ECA EIA-501-A
Recommended Practice for the Measurement of X-Radiation from Raster-Scanned Direct-View Data Display Cathode-Ray Tubes
Organization:
ECIA - Electronic Components Industry Association
Year: 2001
Abstract: This test method applies to the measurement of x-radiation emitted from raster-scanned dired-view data cathode-ray tubes. For some applications the test procedures described in EIA-503 "Recommended Practice for Measurement of X-Radiation from Direct-View Television Picture Tubes" may be more appropriately used than those described in this Standard.
PURPOSE
The purpose of this Standard is to obtain x-radiation characteristics of raster-scanned direct-view data display cathode-ray tubes in order to predict the levels emitted by tubes when the electrical characteristics of the application are known.
PURPOSE
The purpose of this Standard is to obtain x-radiation characteristics of raster-scanned direct-view data display cathode-ray tubes in order to predict the levels emitted by tubes when the electrical characteristics of the application are known.
Collections
:
Show full item record
| contributor author | ECIA - Electronic Components Industry Association | |
| date accessioned | 2017-09-04T15:17:10Z | |
| date available | 2017-09-04T15:17:10Z | |
| date copyright | 01/01/1990 (R 2001) | |
| date issued | 2001 | |
| identifier other | MLXHCBAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;query=authoCA5893FD081D527369727A00D52FAB6A/handle/yse/16504 | |
| description abstract | This test method applies to the measurement of x-radiation emitted from raster-scanned dired-view data cathode-ray tubes. For some applications the test procedures described in EIA-503 "Recommended Practice for Measurement of X-Radiation from Direct-View Television Picture Tubes" may be more appropriately used than those described in this Standard. PURPOSE The purpose of this Standard is to obtain x-radiation characteristics of raster-scanned direct-view data display cathode-ray tubes in order to predict the levels emitted by tubes when the electrical characteristics of the application are known. | |
| language | English | |
| title | ECA EIA-501-A | num |
| title | Recommended Practice for the Measurement of X-Radiation from Raster-Scanned Direct-View Data Display Cathode-Ray Tubes | en |
| type | standard | |
| page | 18 | |
| status | Active | |
| tree | ECIA - Electronic Components Industry Association:;2001 | |
| contenttype | fulltext |