MS21344
FITTINGS--INSTALLATION OF FLARED TUBE, STRAIGHT THREADED CONNECTORS, DESIGN STANDARD FOR
Organization:
AIR FORCE - 82 - San Antonio Air Logistics Center
Year: 1971
Abstract: This military standard is approved by the Department of Defense and is mandatory on all activities. Selection for all new engineering and design applications and for repetitive use shall be made from this document.
INSTALLATION OF FITTING HAVING THE CONNECTION END IN ACCORDANCE WITH MS33656 IS SIMILAR, EXCEPT THAT THE END IS NOT USED THROUGH BULKHEADS. WRENCH TORQUES FOR ASSEMBLING THE TUBING ARE THE SAME.
NOMINAL USE: AIRFRAME FLUID CONNECTIONS
THIS IS DESIGN STANDARD AND SHALL NOT BE USED AS A PART NUMBER.
PROCEDURE FOR INSTALLATION OF MS33656 FITTING END, STYLE E.
1. LUBRICATE THE GASKET IN APPROPRIATE LIQUID (SEE TABLE II).
2. INSTALL GASKET ON THE FITTING AS SHOWN IN DETAIL 1.
3. SCREW THE FITTING ASSEMBLY INTO THE BOSS UNTIL IT BOTTOMS TIGHTLY ON THE BOSS AS SHOWN IN DETAIL 2.
INSTALLATION OF FITTING HAVING THE CONNECTION END IN ACCORDANCE WITH MS33656 IS SIMILAR, EXCEPT THAT THE END IS NOT USED THROUGH BULKHEADS. WRENCH TORQUES FOR ASSEMBLING THE TUBING ARE THE SAME.
NOMINAL USE: AIRFRAME FLUID CONNECTIONS
THIS IS DESIGN STANDARD AND SHALL NOT BE USED AS A PART NUMBER.
PROCEDURE FOR INSTALLATION OF MS33656 FITTING END, STYLE E.
1. LUBRICATE THE GASKET IN APPROPRIATE LIQUID (SEE TABLE II).
2. INSTALL GASKET ON THE FITTING AS SHOWN IN DETAIL 1.
3. SCREW THE FITTING ASSEMBLY INTO THE BOSS UNTIL IT BOTTOMS TIGHTLY ON THE BOSS AS SHOWN IN DETAIL 2.
Collections
:
Show full item record
contributor author | AIR FORCE - 82 - San Antonio Air Logistics Center | |
date accessioned | 2017-09-04T15:43:14Z | |
date available | 2017-09-04T15:43:14Z | |
date copyright | 08/17/1971 | |
date issued | 1971 | |
identifier other | PLLQDAAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std;query=authoCA5893FDFCDCAC426159DD6EFDEC014A/handle/yse/45467 | |
description abstract | This military standard is approved by the Department of Defense and is mandatory on all activities. Selection for all new engineering and design applications and for repetitive use shall be made from this document. INSTALLATION OF FITTING HAVING THE CONNECTION END IN ACCORDANCE WITH MS33656 IS SIMILAR, EXCEPT THAT THE END IS NOT USED THROUGH BULKHEADS. WRENCH TORQUES FOR ASSEMBLING THE TUBING ARE THE SAME. NOMINAL USE: AIRFRAME FLUID CONNECTIONS THIS IS DESIGN STANDARD AND SHALL NOT BE USED AS A PART NUMBER. PROCEDURE FOR INSTALLATION OF MS33656 FITTING END, STYLE E. 1. LUBRICATE THE GASKET IN APPROPRIATE LIQUID (SEE TABLE II). 2. INSTALL GASKET ON THE FITTING AS SHOWN IN DETAIL 1. 3. SCREW THE FITTING ASSEMBLY INTO THE BOSS UNTIL IT BOTTOMS TIGHTLY ON THE BOSS AS SHOWN IN DETAIL 2. | |
language | English | |
title | MS21344 | num |
title | FITTINGS--INSTALLATION OF FLARED TUBE, STRAIGHT THREADED CONNECTORS, DESIGN STANDARD FOR | en |
type | standard | |
page | 3 | |
status | Active | |
tree | AIR FORCE - 82 - San Antonio Air Logistics Center:;1971 | |
contenttype | fulltext |