MIL-STD-188 -125-1

HIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND-BASED C41 FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS PART 1 FIXED FACILITIES

Organization:
DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo)
Year: 1998

Abstract: This standard establishes minimum requirements and design objectives for high-altitude electromagnetic pulse (HEMP) hardening of fixed1 ground-based facilities that perform critical, time-urgent command, control, communications, computer, and intelligence (C4I) missions. Facilities required to fully comply with the provisions of the standard will be designated by the Joint Chiefs of Staff, a Military Department Headquarters, or a Major Command.
This standard prescribes minimum performance requirements for low-risk protection from mission-aborting damage or upset due to HEMP threat environments defined in MIL-STD-2169. This standard also addresses minimum testing requirements for demonstrating that prescribed performance has been achieved and for verifying that the installed protection subsystem provides the operationally required hardness for the completed facility. If the prescribed testing results in any hardware damage or functional upsets, the operational authority for the facility will make the determination whether the observed event is mission aborting.
This standard defines the design and testing criteria for specifically designated fixed ground-based facilities in HEMP-hardened, critical, time-urgent C4I networks. Such nodes include subscriber terminals and data processing centers, transmitting and receiving communications stations, and relay facilities. The standard applies to both new construction and retrofit of existing facilities. Although only local portions of facility interconnects are addressed, it is assumed that survivable long-haul communications paths, fiber optic links, or other hardened interconnects between facilities will be provided as required for mission accomplishment. Use of the standard for HEMP protection of other ground-based communications-electronics facilities that require HEMP hardening is also encouraged.
Survivable C4I capabilities are essential to a credible military deterrent. This standard supports nuclear survivability objectives by providing a standardized, low-risk protection approach for fixed ground-based facilities in HEMP-hardened C4I networks. These uniform requirements ensure balanced HEMP hardening for all critical facilities in the network. Intended Use: The standard contains minimum requirements and design objectives for low-risk HEMP protection of fixed ground-based facilities that perform critical, time-urgent C4I missions. The purpose is to standardize design, construction, and test of HEMP protection subsystems for these facilities and to thereby ensure the quality and durability of the protection. Low-risk HEMP protection is military unique because it is required only for critical C4I assets that support time-urgent attack warning and retaliatory military missions. While other military and commercial systems may require HEMP protection, there are no commercial requirements for low-risk hardening.
URI: http://yse.yabesh.ir/std;query=authoF237659669B749A96159DD6EFDEC014A/handle/yse/132335
Subject: Continuous wave immersion
Collections :
  • DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo)
  • Download PDF : (1.115Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    MIL-STD-188 -125-1

Show full item record

contributor authorDOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo)
date accessioned2017-09-04T17:08:52Z
date available2017-09-04T17:08:52Z
date copyright07/17/1998
date issued1998
identifier otherBZMJFAAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=authoF237659669B749A96159DD6EFDEC014A/handle/yse/132335
description abstractThis standard establishes minimum requirements and design objectives for high-altitude electromagnetic pulse (HEMP) hardening of fixed1 ground-based facilities that perform critical, time-urgent command, control, communications, computer, and intelligence (C4I) missions. Facilities required to fully comply with the provisions of the standard will be designated by the Joint Chiefs of Staff, a Military Department Headquarters, or a Major Command.
This standard prescribes minimum performance requirements for low-risk protection from mission-aborting damage or upset due to HEMP threat environments defined in MIL-STD-2169. This standard also addresses minimum testing requirements for demonstrating that prescribed performance has been achieved and for verifying that the installed protection subsystem provides the operationally required hardness for the completed facility. If the prescribed testing results in any hardware damage or functional upsets, the operational authority for the facility will make the determination whether the observed event is mission aborting.
This standard defines the design and testing criteria for specifically designated fixed ground-based facilities in HEMP-hardened, critical, time-urgent C4I networks. Such nodes include subscriber terminals and data processing centers, transmitting and receiving communications stations, and relay facilities. The standard applies to both new construction and retrofit of existing facilities. Although only local portions of facility interconnects are addressed, it is assumed that survivable long-haul communications paths, fiber optic links, or other hardened interconnects between facilities will be provided as required for mission accomplishment. Use of the standard for HEMP protection of other ground-based communications-electronics facilities that require HEMP hardening is also encouraged.
Survivable C4I capabilities are essential to a credible military deterrent. This standard supports nuclear survivability objectives by providing a standardized, low-risk protection approach for fixed ground-based facilities in HEMP-hardened C4I networks. These uniform requirements ensure balanced HEMP hardening for all critical facilities in the network. Intended Use: The standard contains minimum requirements and design objectives for low-risk HEMP protection of fixed ground-based facilities that perform critical, time-urgent C4I missions. The purpose is to standardize design, construction, and test of HEMP protection subsystems for these facilities and to thereby ensure the quality and durability of the protection. Low-risk HEMP protection is military unique because it is required only for critical C4I assets that support time-urgent attack warning and retaliatory military missions. While other military and commercial systems may require HEMP protection, there are no commercial requirements for low-risk hardening.
languageEnglish
titleMIL-STD-188 -125-1num
titleHIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND-BASED C41 FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS PART 1 FIXED FACILITIESen
typestandard
page107
statusActive
treeDOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo):;1998
contenttypefulltext
subject keywordsContinuous wave immersion
subject keywordsElectric surge arrester
subject keywordsElectromagnetic barrier
subject keywordsFacility HEMP shield
subject keywordsHardening
subject keywordsHardness verification
subject keywordsHigh-altitude electromagnetic pulse
subject keywordsLow-risk HEMP protection
subject keywordsMission-critical systems
subject keywordsNuclear survivability
subject keywordsPOE
subject keywordsPOE protective device
subject keywordsPulsed current injection
subject keywordsShielding effectiveness
subject keywordsSpecial protective measures
subject keywordsSurvivability/vulnerability
subject keywordsTransient suppression/attenuation device
subject keywordsWaveguide below cutoff
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian