IEEE Standard Test Procedures for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V - Redline

IEEE Std C37.09-2018 (Revision of IEEE Std C37.09-1999) - Redline

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2019

Abstract: The testing procedures for all high-voltage circuit breakers that include voltage ratings above 1000 V ac and comprise both indoor and outdoor types having the preferred ratings as listed in IEEE Std C37.04(TM) are covered. Typical circuit breakers covered by these standards have maximum voltage ratings from 4.76 kV through 800 kV, and continuous current ratings of 600 A through 5000 A associated with the various maximum voltage ratings. The test procedures verify all assigned ratings, including continuous current, dielectric withstand voltages, short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. Production test procedures are also included. This standard does not cover generator circuit breakers as these are covered in IEC/IEEE 62271-37-013. (Note: IEEE Std C37.09-2018 requires the use of a color monitor (and color printer) to view many of the graphics contained in this standard. Color is essential to the understanding of the graphics.)
URI: http://yse.yabesh.ir/std;query=authoF2377D8669B749A/handle/yse/273700
Subject: arcing time
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (11.13Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE Standard Test Procedures for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V - Redline

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2019-07-25T07:26:33Z
date available2019-07-25T07:26:33Z
date issued2019
identifier isbn978-1-5044-5824
identifier other08716852.pdf
identifier urihttp://yse.yabesh.ir/std;query=authoF2377D8669B749A/handle/yse/273700
description abstractThe testing procedures for all high-voltage circuit breakers that include voltage ratings above 1000 V ac and comprise both indoor and outdoor types having the preferred ratings as listed in IEEE Std C37.04(TM) are covered. Typical circuit breakers covered by these standards have maximum voltage ratings from 4.76 kV through 800 kV, and continuous current ratings of 600 A through 5000 A associated with the various maximum voltage ratings. The test procedures verify all assigned ratings, including continuous current, dielectric withstand voltages, short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. Production test procedures are also included. This standard does not cover generator circuit breakers as these are covered in IEC/IEEE 62271-37-013. (Note: IEEE Std C37.09-2018 requires the use of a color monitor (and color printer) to view many of the graphics contained in this standard. Color is essential to the understanding of the graphics.)
languageEnglish
titleIEEE Standard Test Procedures for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V - Redlineen
titleIEEE Std C37.09-2018 (Revision of IEEE Std C37.09-1999) - Redlinenum
typeStandard
page119
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2019
contenttypeFulltext
subject keywordsarcing time
subject keywordsdirect test
subject keywordsIEEE C37.09(TM)
subject keywordsmechanical endurance
subject keywordsoperating duty
subject keywordspower frequency
subject keywordsshort-circuit current
subject keywordsshort-line fault
subject keywordssingle-phase testing
subject keywordssynthetic test
subject keywordstest data reporting
subject keywordsthree-phase testing
subject keywordstransient recovery voltage
subject keywordsunit test
subject keywordsIEEE Standards
subject keywordsCircuit breakers
subject keywordsHigh-voltage techniques
subject keywordsFault diagnosis
subject keywordsAC machines
subject keywordsTesting