IEEE Guide for Field Testing of Laminated Dielectric, Shielded AC Power Cable Systems Rated 5 kV to 500 kV Using High Voltage Direct Current (HVDC)
IEEE Std 400.1-2018 (Revision of IEEE Std 400.1-2007)
Year: 2019
Abstract: The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated, dielectric-insulated power cable systems rated 5 kV to 500 kV are presented in this guide. It applies to all types of laminated power cable systems such as paper insulated, lead covered, pipe-type, and pressurized cables that are intended for the transmission or distribution of ac electric power. The tabulated test levels assume that the cable systems have an effectively grounded neutral system or a grounded metallic shield.
Subject: cable
-
Statistics
IEEE Guide for Field Testing of Laminated Dielectric, Shielded AC Power Cable Systems Rated 5 kV to 500 kV Using High Voltage Direct Current (HVDC)
Show full item record
| contributor author | IEEE - The Institute of Electrical and Electronics Engineers, Inc. | |
| date accessioned | 2019-07-25T07:26:33Z | |
| date available | 2019-07-25T07:26:33Z | |
| date issued | 2019 | |
| identifier isbn | 978-1-5044-5347 | |
| identifier other | 08633029.pdf | |
| identifier uri | http://yse.yabesh.ir/std;query=authoF2377D8669B749A/handle/yse/273701 | |
| description abstract | The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated, dielectric-insulated power cable systems rated 5 kV to 500 kV are presented in this guide. It applies to all types of laminated power cable systems such as paper insulated, lead covered, pipe-type, and pressurized cables that are intended for the transmission or distribution of ac electric power. The tabulated test levels assume that the cable systems have an effectively grounded neutral system or a grounded metallic shield. | |
| language | English | |
| title | IEEE Guide for Field Testing of Laminated Dielectric, Shielded AC Power Cable Systems Rated 5 kV to 500 kV Using High Voltage Direct Current (HVDC) | en |
| title | IEEE Std 400.1-2018 (Revision of IEEE Std 400.1-2007) | num |
| type | Standard | |
| page | 23 | |
| tree | IEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2019 | |
| contenttype | Fulltext | |
| subject keywords | cable | |
| subject keywords | cable installation | |
| subject keywords | cable maintenance | |
| subject keywords | cable tests | |
| subject keywords | field test procedures | |
| subject keywords | HVDC tests | |
| subject keywords | IEEE 400.1(TM) | |
| subject keywords | insulated cable | |
| subject keywords | power cable systems | |
| subject keywords | shielded power cable systems | |
| subject keywords | IEEE Standards | |
| subject keywords | Power cables | |
| subject keywords | Power measurement | |
| subject keywords | Testing | |
| subject keywords | Dielectrics | |
| subject keywords | Lamination | |
| subject keywords | HVDC transmission | |
| subject keywords | Maintenance engineering | |
| subject keywords | Cable insulation | |
| identifier DOI | 10.1109/IEEESTD.2019.8633029 |