IEEE Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V

IEEE Std C37.04-2018 (Revision of IEEE Std C37.04-1999)

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2019

Abstract: The rating structure for all high-voltage circuit breakers, which include all voltage ratings above 1000 V ac and comprise both indoor and outdoor types, is covered in this standard. Preferred ratings are also provided. Typical circuit breakers covered by these standards have maximum voltage ratings ranging from 4.76 kV through 800 kV, and continuous current ratings of 600 A, 1200 A, 2000 A, 3000 A, and 4000 A associated with the various maximum voltage ratings. The rating structure establishes the basis for all assigned ratings, including continuous current, insulation capability (formerly dielectric withstand voltages), short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. Generator circuit breakers are covered by IEC/IEEE Std 62271-37-013.
URI: http://yse.yabesh.ir/std;query=authoF2377D8669B749A/handle/yse/276503
Subject: capacitive current switching
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (4.246Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2020-06-18T16:56:29Z
date available2020-06-18T16:56:29Z
date issued2019
identifier isbn978-1-5044-5824
identifier other08726456.pdf
identifier urihttp://yse.yabesh.ir/std;query=authoF2377D8669B749A/handle/yse/276503
description abstractThe rating structure for all high-voltage circuit breakers, which include all voltage ratings above 1000 V ac and comprise both indoor and outdoor types, is covered in this standard. Preferred ratings are also provided. Typical circuit breakers covered by these standards have maximum voltage ratings ranging from 4.76 kV through 800 kV, and continuous current ratings of 600 A, 1200 A, 2000 A, 3000 A, and 4000 A associated with the various maximum voltage ratings. The rating structure establishes the basis for all assigned ratings, including continuous current, insulation capability (formerly dielectric withstand voltages), short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. Generator circuit breakers are covered by IEC/IEEE Std 62271-37-013.
languageEnglish
titleIEEE Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 Ven
titleIEEE Std C37.04-2018 (Revision of IEEE Std C37.04-1999)num
typeStandard
page122
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2019
contenttypeFulltext
subject keywordscapacitive current switching
subject keywordsoutdoor
subject keywordstransient recovery voltage
subject keywordsrelated capabilities
subject keywordspower frequency
subject keywordsratings
subject keywordsoperating duty
subject keywordsmechanical endurance
subject keywordsindoor
subject keywordsshort-line fault
subject keywordsinsulation capability
subject keywordsinterrupting time
subject keywordsIEEE C37.04
subject keywordsshort-circuit current
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian