Now showing items 321-340 of 346

    • NEMA FU 1 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2012
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This standards publication covers the following fuses:
      a. Class G, H, J, K, L, R, T, and CC low voltage cartridge fuses rated 600 volts or less, alternating current and direct current.
      b. Fuses for photovoltaic ...
    • NEMA VE 2 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2006
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This publication addresses shipping, handling, storing, and installing cable tray systems. Information on maintenance and system modification is also provided.
      Abbreviations used in this standard are as follows:
      &# ...
    • NEMA HP 3 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2012
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This standards publication covers specific requirements for PTFE (polytetrafluoroethylene) insulated solid and stranded wire designed for the internal wiring of high reliability electrical and electronic equipment. This ...
    • NEMA ICS 15.1 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2012
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: These guidelines are provided to facilitate movement, handling, installation, and maintenance of medium voltage fire pump controllers at the job site and to help avoid personal injury and equipment damage during these ...
    • NEMA NTCIP 1209 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2005
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: The communications between an ITS Management Center or portable computer and a Transportation Sensor System (TSS) is accomplished by using the NTCIP Application Layer services to convey requests to access or modify values ...
      Subject(s) : AASHTO , data elements , ITE , NEMA , NTCIP , sensor , TSS , vehicle detection ,
    • NEMA ICS 4 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2010
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This standard applies to one piece, or modular, or two piece terminal blocks with screw-type or screw-less-type clamping units intended for industrial use, and fixed to a support or to a Printed Circuit Board (PCB) to ...
    • NEMA DC 3 ANNEX A 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2010
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: OVERVIEW
      This annex provides the specifications that are required for a programmable thermostat to be classified as energy efficient.
    • NEMA AB-5 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2011
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: The scope of this standard includes all types of circuit breakers listed to: 1) The UL 489 Molded-Case Circuit Breakers, Molded-Case Switches and Circuit-Breaker Enclosures 2) The UL 1066 Standard for Safety Low-Voltage ...
    • NEMA C82.13 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2002
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This standard provides definitions of terms used in ANSI C78 and C82 series standards for fluorescent lamps and ballasts. Individual standards may also include additional definitions specific to that standard.
    • NEMA SB 2 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2010
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This manual, developed by the Automatic Fire Detection and Alarm Industry of the Signaling, Protection, and Communications Section, provides technical information on basic fire alarm systems in common usage.
      This edition ...
    • NEMA C29.6 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2012
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This standard covers high-voltage pin-type insulators made of wet-process porcelain and used in the transmission and distribution of electrical energy.
    • NEMA TC 7 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2013
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This standard covers several types of high-density polyethylene (HDPE) conduit for use in providing a protective raceway for electrical cables buried underground. The HDPE conduit types in this specification can be installed ...
    • NEMA EW 9 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2012
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This publication defines test methods and labeling requirements for energy consumption of arc welding power sources. These welding power sources are intended to be either connected to a low-voltage supply network or be ...
    • NEMA FI 2 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2004
      Organization : NEMA - National Electrical Manufacturers Association
    • NEMA BU 1.1 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2010
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This Standards Publication covers products for distribution of electric power at 600 volts or less, consisting of enclosed sectionalized prefabricated busbars rated at 100 amperes or more, and associated structures and ...
    • NEMA LA 1 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2009
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: The standards contained in this publication apply to all valve surge arresters for alternating-current systems, including arresters that are an integral part of other apparatus.
    • NEMA WC 27500 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2012
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This standard contains requirements for finished cables. Component wires are covered by other referenced standards. These cables are intended for signal and low-voltage power applications with defined environment or ...
    • NEMA WD 6 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2012
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This Standard covers dimensional requirements for plugs and receptacles rated up to 60 Ampere and 600 Volts. It also includes dimensions for wall plates.
      Also included is the recommended marking for automatically ...
    • NEMA ICS 5 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2010
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: The standards in this part apply to general-purpose mechanical, electromechanical and solid-state devices which are principally used in industrial applications for control-circuit switching and the control of solenoids ...
    • NEMA C29.3 

      Type: standard
      Source: NEMA - National Electrical Manufacturers Association:;2012
      Organization : NEMA - National Electrical Manufacturers Association
      Abstract: This standard covers spool-type insulators made of wet-process porcelain and used in the transmission and distribution of electric energy.