NEMA ICS 4

APPLICATION GUIDELINE FOR TERMINAL BLOCKS

Organization:
NEMA - National Electrical Manufacturers Association
Year: 2010

Abstract: This standard applies to one piece, or modular, or two piece terminal blocks with screw-type or screw-less-type clamping units intended for industrial use, and fixed to a support or to a Printed Circuit Board (PCB) to provide electrical and mechanical connection for the following round, solid, or stranded conductors:
a. Copper conductors only, without special preparation, having a cross section of 24 AWG to 2000 kcmil (0.2 to 1014 mm²), or 30 AWG to 8 AWG (0.05 to 8.37 mm²) for Printed Circuit Board (PCB) terminal blocks.
b. Aluminum (uncoated) conductors only, without special preparation, having a cross section of 12 AWG to 6 AWG (2.5 to 16 mm²) for solid conductors and of 12 AWG to 2000 kcmil (3.3 to 1014 mm²) for stranded conductors.
c. Aluminum (uncoated) and copper conductors, without special preparation, having a cross section of 12 AWG to 6 AWG (2.5 to 16 mm²) for solid conductors and of 12 AWG to 2000 kcmil (3.3 to 1014 mm²) for stranded conductors.
The terminal blocks are intended for use in circuits of rated insulation voltage not exceeding 1000 V AC at a frequency not greater than 60 hertz, or not exceeding 1500 V DC.
This standard does not apply to connectors specifically designed for, and forming, an integral part of equipment, which are dealt with in the relevant equipment standards.
NOTE This standard may be used as a guide for the termination requirements for disconnect type or other special terminal blocks for which there is no standard at this time.
URI: http://yse.yabesh.ir/std;query=author:%22NAVY%20-%206159DD6E273C9FCD0Facili/handle/yse/24054
Collections :
  • NEMA - National Electrical Manufacturers Association
  • Download PDF : (142.7Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NEMA ICS 4

Show full item record

contributor authorNEMA - National Electrical Manufacturers Association
date accessioned2017-09-04T15:23:45Z
date available2017-09-04T15:23:45Z
date copyright01/01/2010
date issued2010
identifier otherNGDNHDAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=author:%22NAVY%20-%206159DD6E273C9FCD0Facili/handle/yse/24054
description abstractThis standard applies to one piece, or modular, or two piece terminal blocks with screw-type or screw-less-type clamping units intended for industrial use, and fixed to a support or to a Printed Circuit Board (PCB) to provide electrical and mechanical connection for the following round, solid, or stranded conductors:
a. Copper conductors only, without special preparation, having a cross section of 24 AWG to 2000 kcmil (0.2 to 1014 mm²), or 30 AWG to 8 AWG (0.05 to 8.37 mm²) for Printed Circuit Board (PCB) terminal blocks.
b. Aluminum (uncoated) conductors only, without special preparation, having a cross section of 12 AWG to 6 AWG (2.5 to 16 mm²) for solid conductors and of 12 AWG to 2000 kcmil (3.3 to 1014 mm²) for stranded conductors.
c. Aluminum (uncoated) and copper conductors, without special preparation, having a cross section of 12 AWG to 6 AWG (2.5 to 16 mm²) for solid conductors and of 12 AWG to 2000 kcmil (3.3 to 1014 mm²) for stranded conductors.
The terminal blocks are intended for use in circuits of rated insulation voltage not exceeding 1000 V AC at a frequency not greater than 60 hertz, or not exceeding 1500 V DC.
This standard does not apply to connectors specifically designed for, and forming, an integral part of equipment, which are dealt with in the relevant equipment standards.
NOTE This standard may be used as a guide for the termination requirements for disconnect type or other special terminal blocks for which there is no standard at this time.
languageEnglish
titleNEMA ICS 4num
titleAPPLICATION GUIDELINE FOR TERMINAL BLOCKSen
typestandard
page20
statusActive
treeNEMA - National Electrical Manufacturers Association:;2010
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian