TIA TIA-455-199

FOTP-199 In-Line Polarization Crosstalk Measurements Method for Polarization-Maintaining Optical Fibers, Components, and Systems

Organization:
TIA - Telecommunications Industry Association
Year: 2012

Abstract: This Standard is applicable to single sections of PM fiber, to cascaded PM fibers, and to PM fibers interconnected with optical devices. It is also applicable to polarization-maintaining components that lack PM fiber pigtails, in which case the measurement is performed on a PM fiber jumper connected to the output of the component. The method requires gently stretching or heating approximately 0.1- 0.3 meters of PM fiber in order to generate at least a fraction of a cycle of phase shift between the fast and slow waves. Measurement applications are described in Annex C. In all applications of this method, the measured crosstalk value represents the accumulated crosstalk at the location along the PM fiber where the stretching or heating is applied, irrespective of the optical fibers and components that follow it.
Hereafter the test device is referred to as the "sample". The sample must include a section of PM fiber along which the polarization crosstalk is to be measured.
This Standard complements FOTP-193, which describes the measurement of polarization crosstalk at a plane beyond the output interface of the sample.
The polarization crosstalk of PM itself, without connectors, tends to be proportional to fiber length. In such cases the proportionality constant, commonly referred to as the "h-parameter," is another measure of PM fiber performance. A test method for h-parameter is the subject of FOTP-192.
This method is restricted to wavelengths greater than or equal to that at which the fiber is effectively single-mode. The cutoff wavelength of an uncabled fiber may be determined by FOTP-80.
URI: http://yse.yabesh.ir/std;quessionid=2340FFB03E809BEAD71C90D802628B45/handle/yse/208006
Collections :
  • TIA - Telecommunications Industry Association
  • Download PDF : (423.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    TIA TIA-455-199

Show full item record

contributor authorTIA - Telecommunications Industry Association
date accessioned2017-09-04T18:25:50Z
date available2017-09-04T18:25:50Z
date copyright12/01/2002 (R 2012)
date issued2012
identifier otherAHSWTEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;quessionid=2340FFB03E809BEAD71C90D802628B45/handle/yse/208006
description abstractThis Standard is applicable to single sections of PM fiber, to cascaded PM fibers, and to PM fibers interconnected with optical devices. It is also applicable to polarization-maintaining components that lack PM fiber pigtails, in which case the measurement is performed on a PM fiber jumper connected to the output of the component. The method requires gently stretching or heating approximately 0.1- 0.3 meters of PM fiber in order to generate at least a fraction of a cycle of phase shift between the fast and slow waves. Measurement applications are described in Annex C. In all applications of this method, the measured crosstalk value represents the accumulated crosstalk at the location along the PM fiber where the stretching or heating is applied, irrespective of the optical fibers and components that follow it.
Hereafter the test device is referred to as the "sample". The sample must include a section of PM fiber along which the polarization crosstalk is to be measured.
This Standard complements FOTP-193, which describes the measurement of polarization crosstalk at a plane beyond the output interface of the sample.
The polarization crosstalk of PM itself, without connectors, tends to be proportional to fiber length. In such cases the proportionality constant, commonly referred to as the "h-parameter," is another measure of PM fiber performance. A test method for h-parameter is the subject of FOTP-192.
This method is restricted to wavelengths greater than or equal to that at which the fiber is effectively single-mode. The cutoff wavelength of an uncabled fiber may be determined by FOTP-80.
languageEnglish
titleTIA TIA-455-199num
titleFOTP-199 In-Line Polarization Crosstalk Measurements Method for Polarization-Maintaining Optical Fibers, Components, and Systemsen
typestandard
page32
statusActive
treeTIA - Telecommunications Industry Association:;2012
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian