JEDEC JESD22-A102D

Accelerated Moisture Resistance - Unbiased Autoclave

Organization:
JEDEC - Solid State Technology Association
Year: 2010

Abstract: This test method applies primarily to moisture resistance evaluations and robustness testing. Samples are subjected to a condensing, highly humid atmosphere under pressure to force moisture into the package to uncover weaknesses such as delamination and metallization corrosion. This test is used to evaluate new packages or packages that have undergone changes in materials (e.g. mold compound, die passivation) or design (e.g., die/paddle sizes). However, this test should not be applied on laminate or tape based packages i.e. FR4 material, polyimide tape or equivalent.
Some cautions should be considered when performing this test and evaluating test results. Failure mechanisms, both internal (e.g., due to plastic package swelling from saturation) and external (e.g., dendritic growth of conducting material between leads), may be produced which are not applicable to the intended application use conditions. Most semiconductor components are not rated for field applications conditions exceeding 95% RH, including condensing moisture such as rain or fog. The combination of high humidity, high temperature (>Tg) and high pressure may produce unrealistic material failures because absorbed moisture typically decreases the glass transition temperature for most polymeric materials. Extrapolation of autoclave test results to arrive at an application life should be accomplished with care.
The purpose of the "Unbiased Autoclave Test" is performed to evaluate the moisture resistance integrity of non-hermetic packaged solid state devices using moisture condensing or moisture saturated steam environments. It is a highly accelerated test which employs conditions of pressure, humidity and temperature under condensing conditions to accelerate moisture penetration through the external protective material (encapsulant or seal) or along the interface between the external protective material and the metallic conductors passing through it. This test is used to identify failure mechanisms internal to the package and is destructive.
URI: http://yse.yabesh.ir/std;quessionid=2A40ear/handle/yse/76284
Collections :
  • JEDEC - Solid State Technology Association
  • Download PDF : (121.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    JEDEC JESD22-A102D

Show full item record

contributor authorJEDEC - Solid State Technology Association
date accessioned2017-09-04T16:12:59Z
date available2017-09-04T16:12:59Z
date copyright40483
date issued2010
identifier otherSQKSEDAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;quessionid=2A40ear/handle/yse/76284
description abstractThis test method applies primarily to moisture resistance evaluations and robustness testing. Samples are subjected to a condensing, highly humid atmosphere under pressure to force moisture into the package to uncover weaknesses such as delamination and metallization corrosion. This test is used to evaluate new packages or packages that have undergone changes in materials (e.g. mold compound, die passivation) or design (e.g., die/paddle sizes). However, this test should not be applied on laminate or tape based packages i.e. FR4 material, polyimide tape or equivalent.
Some cautions should be considered when performing this test and evaluating test results. Failure mechanisms, both internal (e.g., due to plastic package swelling from saturation) and external (e.g., dendritic growth of conducting material between leads), may be produced which are not applicable to the intended application use conditions. Most semiconductor components are not rated for field applications conditions exceeding 95% RH, including condensing moisture such as rain or fog. The combination of high humidity, high temperature (>Tg) and high pressure may produce unrealistic material failures because absorbed moisture typically decreases the glass transition temperature for most polymeric materials. Extrapolation of autoclave test results to arrive at an application life should be accomplished with care.
The purpose of the "Unbiased Autoclave Test" is performed to evaluate the moisture resistance integrity of non-hermetic packaged solid state devices using moisture condensing or moisture saturated steam environments. It is a highly accelerated test which employs conditions of pressure, humidity and temperature under condensing conditions to accelerate moisture penetration through the external protective material (encapsulant or seal) or along the interface between the external protective material and the metallic conductors passing through it. This test is used to identify failure mechanisms internal to the package and is destructive.
languageEnglish
titleJEDEC JESD22-A102Dnum
titleAccelerated Moisture Resistance - Unbiased Autoclaveen
typestandard
page12
statusActive
treeJEDEC - Solid State Technology Association:;2010
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian