Now showing items 161-180 of 255

    • UFC 4-510-01 CHANGE 4 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2011
      Organization : UFC - Unified Facilities Criteria
      Abstract: GENERAL.
      This section provides general guidance on Department of Defense (DoD) policies and procedures for design and construction of Defense Medical Facilities, including medical and dental treatment ...
    • UFC 3-230-15FA CHANGE 1 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2006
      Organization : UFC - Unified Facilities Criteria
      Abstract: Purpose and scope.
      This manual prescribes standards of design of surface drainage of airfields and heliports. Problems involved in the design of drainage facilities are discussed, and convenient methods ...
    • UFC 3-420-01 CHANGE 8 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2009
      Organization : UFC - Unified Facilities Criteria
      Abstract: PURPOSE AND SCOPE. This UFC provides guidance in the design of plumbing systems, together with the criteria for selecting plumbing materials, fixtures, and equipment and is applicable to all elements of ...
    • UFC 3-270-08 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2004
      Organization : UFC - Unified Facilities Criteria
      Abstract: The system presented in this manual consists of the following components:
      a. Network identification. The process of dividing installation pavement networks into manageable segments for the purpose of performing pavement ...
    • UFC 3-230-07A 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2004
      Organization : UFC - Unified Facilities Criteria
      Abstract: This manual is applicable in selection of all water sources and in planning or performing construction of supply systems. Other manuals in this series are:
      TM 5-813-3/AFM 88-10, Vol. 3--Water Treatment
      TM 5-813-4/AFM ...
    • UFC 4-020-01 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2008
      Organization : UFC - Unified Facilities Criteria
      Abstract: Design Criteria Development. This UFC includes a process for defining the design criteria for a protective system that protects important assets associated with a permanent facility or one in an expeditionary ...
    • UFC 3-310-01 CHANGE 1 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2005
      Organization : UFC - Unified Facilities Criteria
      Abstract: PURPOSE AND SCOPE. This UFC provides structural loading data for the planning, design and construction of buildings for the Department of Defense (DOD). The loading data includes available site-specific ...
    • UFC 3-130-05 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2004
      Organization : UFC - Unified Facilities Criteria
      Abstract: This manual applies to all U.S. Army and U.S. Air Force installations in the Arctic and Subarctic. Topics covered include water supply, wastewater collection, treatment and disposal, fire protection, utility distribution ...
    • UFC 3-130-02 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2004
      Organization : UFC - Unified Facilities Criteria
      Abstract: The procedure is applicable to both Army and Air Force facilities.
      Purpose.
      This manual describes the procedure for selecting sites for military facilities in arctic and subarctic regions.
    • UFC 4-021-01 CHANGE 1 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2010
      Organization : UFC - Unified Facilities Criteria
      Abstract: This UFC provides the design, operation, and maintenance requirements of MNS for DOD facilities. The requirement for a MNS is established by UFC 04-010-01. This document is intended to assist in the design of systems that ...
    • UFC 3-210-02 CHANGE 1 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2010
      Organization : UFC - Unified Facilities Criteria
      Abstract: PURPOSE AND SCOPE. This document provides guidance for designing parking areas and other facilities required for on -site vehicular circulation and station ing. These instructions define the non-organizational or privately ...
    • UFC 3-440-03N CHANGE 1 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2005
      Organization : UFC - Unified Facilities Criteria
      Abstract: PURPOSE AND SCOPE.
      This UFC is comprised of two sections. Chapter 1 introduces this UFC and provides a listing of references to other Tri-Service documents closely related to the subject. Appendix A ...
      Subject(s) : Heating systems , Passive solar design procedures , Solar design procedures ,
    • UFC 4-022-01 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2005
      Organization : UFC - Unified Facilities Criteria
      Abstract: PURPOSE
      This UFC presents a unified approach to the design of Entry Control Facilities (ECFs). The term “Entry Control Facilities” encompasses the overall layout, organization, infrastructure, ...
    • UFC 4-213-10 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2002
      Organization : UFC - Unified Facilities Criteria
      Abstract: This section deals with the selection of an exact location and type of drydock construction. It is assumed that the general vicinity, such as a specific shipyard, has been selected, that the size of ship to be accommodated ...
    • UFC 3-230-10A 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2004
      Organization : UFC - Unified Facilities Criteria
      Abstract: Purpose and scope.
      This manual provides criteria for design and construction of potable water distribution systems for fixed military installations. Within the context of this manual, a water ...
    • UFC 3-220-01N 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2005
      Organization : UFC - Unified Facilities Criteria
      Abstract: Information contained in this UFC is directed toward construction usually undertaken on military reservations, although it is sufficiently general to permit its use on a wide variety of construction projects. Some of the ...
    • UFC 4-150-02 CHANGE 4 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2011
      Organization : UFC - Unified Facilities Criteria
      Abstract: PURPOSE.
      This UFC provides design criteria and guidance in the design of utility systems for piers, wharves, and drydocks. Criteria are given for Type I Piers (Fueling, Ammunition, and Supply); Type ...
    • UFC 4-152-01 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2005
      Organization : UFC - Unified Facilities Criteria
      Abstract: This UFC contains descriptions and design criteria for pier and wharf construction, including subsidiary, contiguous, and auxiliary structures. Loading details, regulations, furnishings, appurtenances, and other information ...
    • UFC 4-740-16 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2005
      Organization : UFC - Unified Facilities Criteria
      Abstract: This UFC provides guidelines for evaluating, planning, and designing Military Recreation Centers (MRCs). The information in this Guide applies to the design of all new construction projects as well as renovation projects. ...
    • UFC 3-580-10 CHANGE 3 

      Type: standard
      Source: UFC - Unified Facilities Criteria:;2005
      Organization : UFC - Unified Facilities Criteria
      Abstract: This document cites and supplements existing Government and Commercial standards and specifications governing architectural, mechanical, and electrical requirements for design of NMCI required Entrance Facilities (EF) and ...