IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications - Redline
IEEE Std 485-2020 (Revision of IEEE Std 485-2010) - Redline
Year: 2020
Abstract: Methods for defining the dc load and for sizing a lead-acid battery to supply that load for stationary battery applications in float service are described in this recommended practice. Some factors relating to cell selection are provided for consideration. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice. Design of the dc system and sizing of the battery charger(s) are also beyond the scope of this recommended practice.
Subject: stationary applications
-
Statistics
IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications - Redline
Show full item record
| contributor author | IEEE - The Institute of Electrical and Electronics Engineers, Inc. | |
| date accessioned | 2022-02-15T19:00:02Z | |
| date available | 2022-02-15T19:00:02Z | |
| date copyright | 5 June 2020 | |
| date issued | 2020 | |
| identifier other | 09169935.pdf | |
| identifier uri | http://yse.yabesh.ir/std;quessioutho4703177793325273135A68A10958014A/handle/yse/300203 | |
| description abstract | Methods for defining the dc load and for sizing a lead-acid battery to supply that load for stationary battery applications in float service are described in this recommended practice. Some factors relating to cell selection are provided for consideration. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice. Design of the dc system and sizing of the battery charger(s) are also beyond the scope of this recommended practice. | |
| language | English | |
| title | IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications - Redline | en |
| title | IEEE Std 485-2020 (Revision of IEEE Std 485-2010) - Redline | num |
| type | Standard | |
| page | 99 | |
| tree | IEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2020 | |
| contenttype | Fulltext | |
| subject keywords | stationary applications | |
| subject keywords | sizing | |
| subject keywords | cell selection | |
| subject keywords | rated capacity | |
| subject keywords | vented lead-acid (VLA) | |
| subject keywords | valve-regulated lead-acid (VRLA) cell | |
| subject keywords | vented battery | |
| subject keywords | dc load | |
| subject keywords | full-float operation | |
| subject keywords | battery duty cycle | |
| subject keywords | IEEE 485 | |
| subject keywords | lead-acid batteries |