Abstract: Abstract:
A mishap occurred in a large (18' X 20') autoclave resulting in damage to government property of approximately $23K. The mishap was likely the result of a small amount of accumulated debris around a pneumatic valve, coupled with a minor error in pressure system logic, which failed to alert operators of the event prior to failure.
A mishap occurred in a large (18' X 20') autoclave resulting in damage to government property of approximately $23K. The mishap was likely the result of a small amount of accumulated debris around a pneumatic valve, coupled with a minor error in pressure system logic, which failed to alert operators of the event prior to failure.
Subject: Mishap Reporting
Show full item record
| contributor author | NASA - National Aeronautics and Space Administration (NASA) | |
| date accessioned | 2017-09-04T16:38:18Z | |
| date available | 2017-09-04T16:38:18Z | |
| date copyright | 37908 | |
| date issued | 2003 | |
| identifier other | VHWEQCAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/101830 | |
| description abstract | Abstract: A mishap occurred in a large (18' X 20') autoclave resulting in damage to government property of approximately $23K. The mishap was likely the result of a small amount of accumulated debris around a pneumatic valve, coupled with a minor error in pressure system logic, which failed to alert operators of the event prior to failure. | |
| language | English | |
| title | NASA-LLIS-1383 | num |
| title | Lessons Learned – Autoclave Purge Blower Failure | en |