CSA A123.21-10

Standard test method for the dynamic wind uplift resistance of membrane-roofing systems - Second Edition; Update No. 1: December 2010

Organization:
CSA - CSA Group
Year: 2010

Abstract: This test method determines the wind uplift resistance of membrane-roofing systems when subjected to dynamic wind load cycles.
The test methods are
(a) Method 1: mechanically attached membrane-roofing systems; and
(b) Method 2: adhered membrane-roofing systems.
The roofing system consists of a deck and roofing membrane. It includes components such as vapour barriers or retarders, insulation, cover board, etc. It is subjected to a dynamic load sequence that has been developed based on wind pressure records, simulating the effects of wind on membrane-roof assemblies.
Note: The roof membrane may be designated as the plane of air tightness.
Method 1: Testing in accordance with this test method is limited to mechanically attached, reinforced membrane systems having a fastener row separation not greater than 2896 mm (114 in) and fastener in-line spacing not greater than 610 mm (24 in).
Method 2: Testing in accordance with this test method is limited to roof components adhered as a means of resisting wind uplift, without the use of mechanical fasteners or ballast.
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
The values given in SI (metric) units are the standard. The values given in parentheses are for information only.
URI: https://yse.yabesh.ir/std/handle/yse/103528
Collections :
  • CSA - CSA Group
  • Download PDF : (1.738Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA A123.21-10

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T16:39:49Z
date available2017-09-04T16:39:49Z
date copyright2010.05.01
date issued2010
identifier otherVMDTUDAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/103528
description abstractThis test method determines the wind uplift resistance of membrane-roofing systems when subjected to dynamic wind load cycles.
The test methods are
(a) Method 1: mechanically attached membrane-roofing systems; and
(b) Method 2: adhered membrane-roofing systems.
The roofing system consists of a deck and roofing membrane. It includes components such as vapour barriers or retarders, insulation, cover board, etc. It is subjected to a dynamic load sequence that has been developed based on wind pressure records, simulating the effects of wind on membrane-roof assemblies.
Note: The roof membrane may be designated as the plane of air tightness.
Method 1: Testing in accordance with this test method is limited to mechanically attached, reinforced membrane systems having a fastener row separation not greater than 2896 mm (114 in) and fastener in-line spacing not greater than 610 mm (24 in).
Method 2: Testing in accordance with this test method is limited to roof components adhered as a means of resisting wind uplift, without the use of mechanical fasteners or ballast.
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
The values given in SI (metric) units are the standard. The values given in parentheses are for information only.
languageEnglish
titleCSA A123.21-10num
titleStandard test method for the dynamic wind uplift resistance of membrane-roofing systems - Second Edition; Update No. 1: December 2010en
typestandard
page46
statusActive
treeCSA - CSA Group:;2010
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian