IEEE C57.139
Guide for Dissolved Gas Analysis in Transformer Load Tap Changers
Year: 2010
Abstract: This guide discusses and recommends methods of testing and evaluating dissolved gases in mineral based transformer oils found in Load Tap Changers (LTCs). General types of LTC mechanisms, breathing configurations, and electrical design will be included for evaluation criteria in determining when mechanical damage or failure has occurred. Dissolved Gas Analysis (DGA) of the oil in the LTC is required. This guide will not be manufacturer specific, rather category specific.
Purpose
The purpose of this guide is to assist the responsible parties who are in charge of the operation and maintenance decisions in evaluating the condition of a load tap changer (LTC) without the need to deenergize the transformer to inspect the LTC in question. Additionally, repairs to the LTC can be made in a timely fashion based on accurate interpretation of the gas analysis minimizing premature repairs or post failure rebuilds.
Purpose
The purpose of this guide is to assist the responsible parties who are in charge of the operation and maintenance decisions in evaluating the condition of a load tap changer (LTC) without the need to deenergize the transformer to inspect the LTC in question. Additionally, repairs to the LTC can be made in a timely fashion based on accurate interpretation of the gas analysis minimizing premature repairs or post failure rebuilds.
Subject: DGA
Show full item record
| contributor author | IEEE - The Institute of Electrical and Electronics Engineers, Inc. | |
| date accessioned | 2017-09-04T16:40:43Z | |
| date available | 2017-09-04T16:40:43Z | |
| date copyright | 40521 | |
| date issued | 2010 | |
| identifier other | VNUABEAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/104161 | |
| description abstract | This guide discusses and recommends methods of testing and evaluating dissolved gases in mineral based transformer oils found in Load Tap Changers (LTCs). General types of LTC mechanisms, breathing configurations, and electrical design will be included for evaluation criteria in determining when mechanical damage or failure has occurred. Dissolved Gas Analysis (DGA) of the oil in the LTC is required. This guide will not be manufacturer specific, rather category specific. Purpose The purpose of this guide is to assist the responsible parties who are in charge of the operation and maintenance decisions in evaluating the condition of a load tap changer (LTC) without the need to deenergize the transformer to inspect the LTC in question. Additionally, repairs to the LTC can be made in a timely fashion based on accurate interpretation of the gas analysis minimizing premature repairs or post failure rebuilds. | |
| language | English | |
| title | IEEE C57.139 | num |
| title | Guide for Dissolved Gas Analysis in Transformer Load Tap Changers | en |
| type | standard | |
| page | 32 | |
| status | Active | |
| tree | IEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2010 | |
| contenttype | fulltext | |
| subject keywords | DGA | |
| subject keywords | dissolved gas-in-oil | |
| subject keywords | IEEE C57.139 | |
| subject keywords | load tap changer | |
| subject keywords | LTC | |
| subject keywords | on-load tap changer |