description abstractThis specification covers two types of two-wire electrically heated pitot static tubes identified as follows:
        Type I  Rated Voltage - 24 volt, direct current (DC)                 AN5814-2        "L" shaped                 AN5816-2        Straight          Type II Rated Voltage - 115 volt, 400 Hz, single-phase                                  alternating current (AC)                 AN5814-3         "L" shaped                 AN5816-3         Straight


Intended Use: Pitot static tubes covered by this specification are intended for use in aircraft in conjunction with airspeed indicators for temperatures as low as −65°C (−85°F). The tubes are also used as a source of static pressure for altimeters and climb indicators.