NASA-LLIS-0506

Lessons Learned - Use of Documentation to Determine whether or not a Product Contains Hazardous Substances

Organization:
NASA - National Aeronautics and Space Administration (NASA)
Year: 1994

Abstract: Description of Driving Event:
On 1-28-93, during normal testing in the Model Preparation Area (MPA) of the 16' Transonic tunnel, oil from a turboprop simulator model was vented into the atmosphere. The vented oil was MIL-7808- H, the same type as used in past model tests. The turboprop simulators have no oil scavenging system, therefore, it is standard practice to vent oil from the simulators.
When preparing to clean instrumentation fouled with the vented oil, it was determined that MIL- 7808-H oil contains Tricresylphosphate, a hazardous substance absorbable through the skin and capable of causing paralysis. After LaRC Environmental Health Personnel were contacted to determine proper protective measures, the MPA room was cleaned of all residual oil. There were no personnel injuries resulting from this incident.
URI: https://yse.yabesh.ir/std/handle/yse/116294
Subject: Hazardous/Toxic Waste/Materials
Collections :
  • NASA - National Aeronautics and Space Administration (NASA)
  • Download PDF : (13.16Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NASA-LLIS-0506

Show full item record

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T16:52:55Z
date available2017-09-04T16:52:55Z
date copyright07/12/1994
date issued1994
identifier otherWUBEQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/116294
description abstractDescription of Driving Event:
On 1-28-93, during normal testing in the Model Preparation Area (MPA) of the 16' Transonic tunnel, oil from a turboprop simulator model was vented into the atmosphere. The vented oil was MIL-7808- H, the same type as used in past model tests. The turboprop simulators have no oil scavenging system, therefore, it is standard practice to vent oil from the simulators.
When preparing to clean instrumentation fouled with the vented oil, it was determined that MIL- 7808-H oil contains Tricresylphosphate, a hazardous substance absorbable through the skin and capable of causing paralysis. After LaRC Environmental Health Personnel were contacted to determine proper protective measures, the MPA room was cleaned of all residual oil. There were no personnel injuries resulting from this incident.
languageEnglish
titleNASA-LLIS-0506num
titleLessons Learned - Use of Documentation to Determine whether or not a Product Contains Hazardous Substancesen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1994
contenttypefulltext
subject keywordsHazardous/Toxic Waste/Materials
subject keywordsOccupational Health
subject keywordsTest Facility