API RP 756

Management of Hazards Associated with Location of Process Plant Tents - FIRST EDITION

Organization:
API - American Petroleum Institute
Year: 2014

Abstract: General
This Recommended Practice (RP) provides guidance for managing the risk from explosions, fires and toxic material releases to on-site personnel located in tents. The term "tent" is used to describe a wide range of structures and is defined in 3.18. This RP was developed for use at refineries, petrochemical and chemical operations, natural gas liquids extraction plants, natural gas liquefaction plants, and other onshore facilities covered by OSHA 29 CFR 1910.119 [1].
The focus of this RP is primarily on process related hazards. However, non-process related hazards may exist which could present risks to tent occupants. Previous incidents have demonstrated that tent occupants are susceptible to injuries from fires originating inside the tent, from tent collapse due to extreme weather, and from falling objects. Some of these hazards are addressed by tent design standards, manufacturer's recommendations, and local regulations. See 5.3 and 5.4 for additional guidance.
Guiding Principles
This RP is based on the following guiding principles.
a) Locate personnel away from process areas consistent with safe and effective operations.
b) Minimize the use of tents intended for occupancy in close proximity to process areas.
c) Manage the occupancy of tents in close proximity to process areas.
d) Design, construct, install, modify, and maintain tents intended for occupancy to mitigate hazards that the tent siting could present to occupants in the event of explosion, fire, and toxic material release.
e) Manage the use of tents intended for occupancy as an integral part of the design, construction, maintenance, and operation of a facility.
Relationship with API RP 752 and API RP 753
The requirements and work processes in API 756 are similar to API 752, Management of Hazards Associated with the Location of Process Plant Permanent Buildings. API 756 uses a similar zoning concept for design/site selection decisions as API 753, Management of Hazards Associated with the Location of Process Plant Portable Buildings. API 756 was written using a similar format as API 752 for consistency between the two documents. In many cases API 756 refers to API 752 and API 753 to avoid duplication.
URI: https://yse.yabesh.ir/std/handle/yse/122203
Collections :
  • API - American Petroleum Institute
  • Download PDF : (864.7Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    API RP 756

Show full item record

contributor authorAPI - American Petroleum Institute
date accessioned2017-09-04T16:58:46Z
date available2017-09-04T16:58:46Z
date copyright2014.09.01
date issued2014
identifier otherXKDSIFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/122203
description abstractGeneral
This Recommended Practice (RP) provides guidance for managing the risk from explosions, fires and toxic material releases to on-site personnel located in tents. The term "tent" is used to describe a wide range of structures and is defined in 3.18. This RP was developed for use at refineries, petrochemical and chemical operations, natural gas liquids extraction plants, natural gas liquefaction plants, and other onshore facilities covered by OSHA 29 CFR 1910.119 [1].
The focus of this RP is primarily on process related hazards. However, non-process related hazards may exist which could present risks to tent occupants. Previous incidents have demonstrated that tent occupants are susceptible to injuries from fires originating inside the tent, from tent collapse due to extreme weather, and from falling objects. Some of these hazards are addressed by tent design standards, manufacturer's recommendations, and local regulations. See 5.3 and 5.4 for additional guidance.
Guiding Principles
This RP is based on the following guiding principles.
a) Locate personnel away from process areas consistent with safe and effective operations.
b) Minimize the use of tents intended for occupancy in close proximity to process areas.
c) Manage the occupancy of tents in close proximity to process areas.
d) Design, construct, install, modify, and maintain tents intended for occupancy to mitigate hazards that the tent siting could present to occupants in the event of explosion, fire, and toxic material release.
e) Manage the use of tents intended for occupancy as an integral part of the design, construction, maintenance, and operation of a facility.
Relationship with API RP 752 and API RP 753
The requirements and work processes in API 756 are similar to API 752, Management of Hazards Associated with the Location of Process Plant Permanent Buildings. API 756 uses a similar zoning concept for design/site selection decisions as API 753, Management of Hazards Associated with the Location of Process Plant Portable Buildings. API 756 was written using a similar format as API 752 for consistency between the two documents. In many cases API 756 refers to API 752 and API 753 to avoid duplication.
languageEnglish
titleAPI RP 756num
titleManagement of Hazards Associated with Location of Process Plant Tents - FIRST EDITIONen
typestandard
page34
statusActive
treeAPI - American Petroleum Institute:;2014
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian