• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • API - American Petroleum Institute
  • View Item
  •   YSE
  • Industrial Standards
  • API - American Petroleum Institute
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

API STD 2510

Design and Construction of LPG Installations - Eighth Edition

Organization:
API - American Petroleum Institute
Year: 2001

Abstract: 1 Scope
This standard covers the design, construction, and location of liquefied petroleum gas (LPG) installations at marine and pipeline terminals, natural gas processing plants, refineries, petrochemical plants, or tank farms. This standard covers storage vessels, loading and unloading systems, piping, or and related equipment.
1.1 The size and type of the installation; the related facilities on the site; the commercial, industrial, and residential population density in the surrounding area; the terrain and climate conditions; and the type of LPG handled shall be considered. Generally speaking, the larger the installation and the greater the population density of the surrounding area, the more stringent are the design requirements.
1.2 Design and construction considerations peculiar to refrigerated storage, including autorefrigerated storage, are covered in Section 9 of this standard.
1.3 In this standard, numerical values are presented with U.S. customary units only. These U.S. customary values are to be regarded as the standard values.
1.4 This standard shall not apply to the design, construction, or relocation of frozen earth pits, underground storage caverns or wells, underground or mounded storage tanks, and aboveground concrete storage tanks.
1.5 This standard does not apply to the following installations:
a. Those covered by NFPA 58 and NFPA 59.
b. U.S. Department of Transportation (DOT) containers.
c. Gas utility company facilities; refinery process equipment; refinery and gas plant processing equipment; and transfer systems from process equipment upstream LPG storage.
d. Those tanks with less than 2000 gallons of storage capacity.
1.6 RETROACTIVITY
The provisions of this standard are intended for application to new installations. This standard can be used to review and evaluate existing storage facilities. However, the feasibility of applying this standard to facilities, equipment, structures, or installations that were already in place or that were in the process of construction or installation before the date of this publication, must be evaluated on a case-by-case basis considering individual circumstances and sites.
1.7 CHARACTERISTICS OF LPG
LPG is customarily handled in a liquid state achieved by its liquefaction under moderate pressure. Upon release of the pressure, LPG is readily converted into the gaseous phase at normal ambient temperature.
1.8 SAFETY
The safety of LPG storage installations is enhanced by the employment of good engineering practices, such as those recommended by this standard, during design and construction.
URI: https://yse.yabesh.ir/std/handle/yse/125682
Collections :
  • API - American Petroleum Institute
  • Download PDF : (322.6Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    API STD 2510

Show full item record

contributor authorAPI - American Petroleum Institute
date accessioned2017-09-04T17:02:11Z
date available2017-09-04T17:02:11Z
date copyright05/01/2001
date issued2001
identifier otherXTKMPAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/125682
description abstract1 Scope
This standard covers the design, construction, and location of liquefied petroleum gas (LPG) installations at marine and pipeline terminals, natural gas processing plants, refineries, petrochemical plants, or tank farms. This standard covers storage vessels, loading and unloading systems, piping, or and related equipment.
1.1 The size and type of the installation; the related facilities on the site; the commercial, industrial, and residential population density in the surrounding area; the terrain and climate conditions; and the type of LPG handled shall be considered. Generally speaking, the larger the installation and the greater the population density of the surrounding area, the more stringent are the design requirements.
1.2 Design and construction considerations peculiar to refrigerated storage, including autorefrigerated storage, are covered in Section 9 of this standard.
1.3 In this standard, numerical values are presented with U.S. customary units only. These U.S. customary values are to be regarded as the standard values.
1.4 This standard shall not apply to the design, construction, or relocation of frozen earth pits, underground storage caverns or wells, underground or mounded storage tanks, and aboveground concrete storage tanks.
1.5 This standard does not apply to the following installations:
a. Those covered by NFPA 58 and NFPA 59.
b. U.S. Department of Transportation (DOT) containers.
c. Gas utility company facilities; refinery process equipment; refinery and gas plant processing equipment; and transfer systems from process equipment upstream LPG storage.
d. Those tanks with less than 2000 gallons of storage capacity.
1.6 RETROACTIVITY
The provisions of this standard are intended for application to new installations. This standard can be used to review and evaluate existing storage facilities. However, the feasibility of applying this standard to facilities, equipment, structures, or installations that were already in place or that were in the process of construction or installation before the date of this publication, must be evaluated on a case-by-case basis considering individual circumstances and sites.
1.7 CHARACTERISTICS OF LPG
LPG is customarily handled in a liquid state achieved by its liquefaction under moderate pressure. Upon release of the pressure, LPG is readily converted into the gaseous phase at normal ambient temperature.
1.8 SAFETY
The safety of LPG storage installations is enhanced by the employment of good engineering practices, such as those recommended by this standard, during design and construction.
languageEnglish
titleAPI STD 2510num
titleDesign and Construction of LPG Installations - Eighth Editionen
typestandard
page34
statusRevised
treeAPI - American Petroleum Institute:;2001
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 