IEEE N42.17C

American National Standard Performance Specifications for Health Physics Instrumentation - Portable Instrumentation for Use in Extreme Environmental Conditions

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2005

Abstract: Foreward
(This Foreword is not a part of ANSI N42.17C-1989, American National Standard Performance Specifications for Health Physics Instrumentation-Portable Instrumentation for Use in Extreme Environmental Conditions.)
This standard is the responsibility of the Accredited Standards Committee N42 on Radiation Instrumentation. Committee N42 delegated the development of the standard to its Subcommittee N42.1 Drafts were reviewed by Committee N42, Subcommittee N42.1, and other interested parties, and the comments received were utilized in producing the standard as finally approved and discussed. Performance criteria contained in this standard were tested for applicability under the standard was approved by Committee N42 letter ballot of February 6, 1989.
At the time it approved this standard, the Accredited Standards Committee on Radiation Instrumentation, N42, had the following members:
Louis Costrell , Chair
Sue Vogel , Administrative Secretary
American Conference of Governmental Industrial Hygienists
Jesse Lieberman
Battelle pacific Northwest Laboratories
Jack M. Selby
Health Physics society
J. B. Horner Kuper
Jack M. Selby ( Alt. )
Institute of Electrical and Electronics Engineers
Louis Costrell
David C. Cook ( Alt. )
Julian Forster ( Alt. )
Anthony J. Spurgin ( Alt. )
Lawrence Berkeley Laboratory
Lee J. Wagner
Lawrence Livermore National Laboratory
Paul L. Phelps
Nuclear Suppliers Association
Kenneth F. Sinclair
Oak Ridge National Laboratory
Hugh R. Brashear
UCLA Center for the Health Sciences
James E. McLaughlin
US Department of the Army
Edward Groeber
US Department of Commerce, National Institute of Standards and Technology
Louis Costrell
US Department of Energy
Gerald Goldstein
US Federal Emergency Management Agency
Carl R. Siebentritt
US Nuclear Regulatory Commission 
Edward C. Wenzinger, Sr.
Members-at-Large 
Joseph G. Bellian
David C. cook
Ernesto A. Corte
John M. Gallagher
Dick A. Mack
Edward J. Vallario
At the time this standard was approved, Subcommittee N42.1 had the following members:
Jack M. Selby , Chair
J. G. Bellian
Edmond Goodale
J. D. Henderson
R. L. Kathren
William Klein
H. W. Patterson
C. R. Siebentritt
The working group for this standard had the following members:
J. M. Selby , Chair
K. L. Swinth , Vice Chair
B. V. Anderson*
J. G. Bellian
M. V. Federline 
J. A. Flanigan
D. M. Fleming
J. A. Jones*
J. N. Little
R. B. Neel
G. J. Oliver
R. D. Terry
R. P. Ulman
C. K. Brown
A. L. Cucchiara
L. M. Earls
J. G. Flaherty
R. L. Kathren
J. L. Kenoyer
*Deceased  
Replaced by another NRC representative
Consultant
The following persons were on the balloting committee that approved this document for submission to the Accredited Standards Committee N42:
J. G. Bellian
H. R. Brashear
D. C. Cook
L. Costrell
J. Forster
J. M. Gallagher
G. Goldstein
E. Groeber
J. B. Horner Kuper
J. Lieberman
D. A. Mack
J. E. McLaughlin
J. M. Selby
C. R. Siebentritt
K. F. Sinclair
A. J. Spurgin
E. J. Vallario
L. J. Wagner
E. C. Wenzinger, Sr.
Scope
This standard establishes minimum acceptable performance criteria for health physics instrumentation for use in ionizing radiation fields under extreme environmental conditions. Included are testing methods to establish the acceptability of each type of instrumentation. This standard does not specify which instruments or systems are required, nor does it consider the number of specific applications of such instruments. This standard supplements the basic performance requirements for health physics instrumentation as specified in ANSI N42.17A [2]. 1 Specifications in this standard are expected to be called for by the user as required and should not be considered as general specifications.
URI: https://yse.yabesh.ir/std/handle/yse/126176
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (190.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE N42.17C

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T17:02:41Z
date available2017-09-04T17:02:41Z
date copyright09/07/1989 (R 2005)
date issued2005
identifier otherXUUQHBAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/126176
description abstractForeward
(This Foreword is not a part of ANSI N42.17C-1989, American National Standard Performance Specifications for Health Physics Instrumentation-Portable Instrumentation for Use in Extreme Environmental Conditions.)
This standard is the responsibility of the Accredited Standards Committee N42 on Radiation Instrumentation. Committee N42 delegated the development of the standard to its Subcommittee N42.1 Drafts were reviewed by Committee N42, Subcommittee N42.1, and other interested parties, and the comments received were utilized in producing the standard as finally approved and discussed. Performance criteria contained in this standard were tested for applicability under the standard was approved by Committee N42 letter ballot of February 6, 1989.
At the time it approved this standard, the Accredited Standards Committee on Radiation Instrumentation, N42, had the following members:
Louis Costrell , Chair
Sue Vogel , Administrative Secretary
American Conference of Governmental Industrial Hygienists
Jesse Lieberman
Battelle pacific Northwest Laboratories
Jack M. Selby
Health Physics society
J. B. Horner Kuper
Jack M. Selby ( Alt. )
Institute of Electrical and Electronics Engineers
Louis Costrell
David C. Cook ( Alt. )
Julian Forster ( Alt. )
Anthony J. Spurgin ( Alt. )
Lawrence Berkeley Laboratory
Lee J. Wagner
Lawrence Livermore National Laboratory
Paul L. Phelps
Nuclear Suppliers Association
Kenneth F. Sinclair
Oak Ridge National Laboratory
Hugh R. Brashear
UCLA Center for the Health Sciences
James E. McLaughlin
US Department of the Army
Edward Groeber
US Department of Commerce, National Institute of Standards and Technology
Louis Costrell
US Department of Energy
Gerald Goldstein
US Federal Emergency Management Agency
Carl R. Siebentritt
US Nuclear Regulatory Commission 
Edward C. Wenzinger, Sr.
Members-at-Large 
Joseph G. Bellian
David C. cook
Ernesto A. Corte
John M. Gallagher
Dick A. Mack
Edward J. Vallario
At the time this standard was approved, Subcommittee N42.1 had the following members:
Jack M. Selby , Chair
J. G. Bellian
Edmond Goodale
J. D. Henderson
R. L. Kathren
William Klein
H. W. Patterson
C. R. Siebentritt
The working group for this standard had the following members:
J. M. Selby , Chair
K. L. Swinth , Vice Chair
B. V. Anderson*
J. G. Bellian
M. V. Federline 
J. A. Flanigan
D. M. Fleming
J. A. Jones*
J. N. Little
R. B. Neel
G. J. Oliver
R. D. Terry
R. P. Ulman
C. K. Brown
A. L. Cucchiara
L. M. Earls
J. G. Flaherty
R. L. Kathren
J. L. Kenoyer
*Deceased  
Replaced by another NRC representative
Consultant
The following persons were on the balloting committee that approved this document for submission to the Accredited Standards Committee N42:
J. G. Bellian
H. R. Brashear
D. C. Cook
L. Costrell
J. Forster
J. M. Gallagher
G. Goldstein
E. Groeber
J. B. Horner Kuper
J. Lieberman
D. A. Mack
J. E. McLaughlin
J. M. Selby
C. R. Siebentritt
K. F. Sinclair
A. J. Spurgin
E. J. Vallario
L. J. Wagner
E. C. Wenzinger, Sr.
Scope
This standard establishes minimum acceptable performance criteria for health physics instrumentation for use in ionizing radiation fields under extreme environmental conditions. Included are testing methods to establish the acceptability of each type of instrumentation. This standard does not specify which instruments or systems are required, nor does it consider the number of specific applications of such instruments. This standard supplements the basic performance requirements for health physics instrumentation as specified in ANSI N42.17A [2]. 1 Specifications in this standard are expected to be called for by the user as required and should not be considered as general specifications.
languageEnglish
titleIEEE N42.17Cnum
titleAmerican National Standard Performance Specifications for Health Physics Instrumentation - Portable Instrumentation for Use in Extreme Environmental Conditionsen
typestandard
page26
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2005
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian