API STD 675
Positive Displacement Pumps - Controlled Volume for Petroleum, Chemical, and Gas Industry Services - Third Edition
Organization:
API - American Petroleum Institute
Year: 2012
Abstract: This standard covers the minimum requirements for reciprocating, controlled volume pumps and pump units for use in the petroleum, petrochemical, and gas industry services. These pumps are either hydraulic diaphragm or packed plunger design. Rotary positive displacement pumps are not included. Diaphragm pumps that use direct mechanical actuation are also excluded.
NOTE See API 674 for positive displacement reciprocating pumps and API 670 for positive displacement rotary pumps.
This standard requires the Purchaser to specify certain details and features. A bullet () at the beginning of a paragraph indicates that either a decision by, or further information from, the Purchaser is required. Further information should be shown on the data sheets (see example in Annex A) or stated in the quotation request and purchase order.
Alternate Designs and Conflicting Requirements are now located in Section 6.
NOTE See API 674 for positive displacement reciprocating pumps and API 670 for positive displacement rotary pumps.
This standard requires the Purchaser to specify certain details and features. A bullet () at the beginning of a paragraph indicates that either a decision by, or further information from, the Purchaser is required. Further information should be shown on the data sheets (see example in Annex A) or stated in the quotation request and purchase order.
Alternate Designs and Conflicting Requirements are now located in Section 6.
Collections
:
Show full item record
| contributor author | API - American Petroleum Institute | |
| date accessioned | 2017-09-04T17:04:55Z | |
| date available | 2017-09-04T17:04:55Z | |
| date copyright | 2012.11.01 | |
| date issued | 2012 | |
| identifier other | BYKUAFAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/128502 | |
| description abstract | This standard covers the minimum requirements for reciprocating, controlled volume pumps and pump units for use in the petroleum, petrochemical, and gas industry services. These pumps are either hydraulic diaphragm or packed plunger design. Rotary positive displacement pumps are not included. Diaphragm pumps that use direct mechanical actuation are also excluded. NOTE See API 674 for positive displacement reciprocating pumps and API 670 for positive displacement rotary pumps. This standard requires the Purchaser to specify certain details and features. A bullet () at the beginning of a paragraph indicates that either a decision by, or further information from, the Purchaser is required. Further information should be shown on the data sheets (see example in Annex A) or stated in the quotation request and purchase order. Alternate Designs and Conflicting Requirements are now located in Section 6. | |
| language | English | |
| title | API STD 675 | num |
| title | Positive Displacement Pumps - Controlled Volume for Petroleum, Chemical, and Gas Industry Services - Third Edition | en |
| type | standard | |
| page | 74 | |
| status | Active | |
| tree | API - American Petroleum Institute:;2012 | |
| contenttype | fulltext |