MIL-T-16315D

TRANSFORMERS, POWER, STEP-DOWN (MISCELLANEOUS, NAVAL SHIPBOARD USE)

Organization:
NAVY - SH - Naval Sea Systems Command (Ship Systems)
Year: 1994

Abstract: This specification covers small, dry type, step-down, power transformers for use on Naval ships.
Transformers shall be of the following types, as specified (see 6.2):
            IL (Indicator light).  (3.14)             CC (Control circuit).  (3.15)             SL (Sight light).  (3.16)             GF (Gun and torpedo firing).  (3.17)             PR (Power rectifier).  (3.18)             TF (Torpedo firing).  (3.19)             SA (Special applications).  (3.20)


Intended Use: The small transformers covered by this specification are intended for use in the following applications: Type IL transformers are intended for 6 volt power supply for indicator lamps on switchboard such as the bull's-eye type. These transformers are also used in ordnance applications. Type CC transformers are intended for use in control circuit applications such as zeroing synchros and input to closing coils for circuit breakers and contactors, where the proper voltage for these appliances is not directly available on the bus. Type SL transformers are intended for use in ordnance applications, specifically for illumination of gun sights, for instrument illumination, and for interior communication and fire control applications. Type GF transformers are intended for use in gun, torpedo, rocket, and depth charge firing systems. Type PR transformers are intended for use as anode transformers, interphase transformers, cathode transformers, and auxiliary transformers for power rectifiers. Type TF transformers are intended for use in isolation of grounds in torpedo firing circuits. Type SA transformers are intended for use as internal components of equipment and having performance characteristics, mounting and size most suited for the specific application.
URI: https://yse.yabesh.ir/std/handle/yse/133476
Subject: Magnet wire
Collections :
  • NAVY - SH - Naval Sea Systems Command (Ship Systems)
  • Download PDF : (952.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    MIL-T-16315D

Show full item record

contributor authorNAVY - SH - Naval Sea Systems Command (Ship Systems)
date accessioned2017-09-04T17:10:00Z
date available2017-09-04T17:10:00Z
date copyright05/24/1994
date issued1994
identifier otherYOJYDAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/133476
description abstractThis specification covers small, dry type, step-down, power transformers for use on Naval ships.
Transformers shall be of the following types, as specified (see 6.2):
            IL (Indicator light).  (3.14)             CC (Control circuit).  (3.15)             SL (Sight light).  (3.16)             GF (Gun and torpedo firing).  (3.17)             PR (Power rectifier).  (3.18)             TF (Torpedo firing).  (3.19)             SA (Special applications).  (3.20)


Intended Use: The small transformers covered by this specification are intended for use in the following applications: Type IL transformers are intended for 6 volt power supply for indicator lamps on switchboard such as the bull's-eye type. These transformers are also used in ordnance applications. Type CC transformers are intended for use in control circuit applications such as zeroing synchros and input to closing coils for circuit breakers and contactors, where the proper voltage for these appliances is not directly available on the bus. Type SL transformers are intended for use in ordnance applications, specifically for illumination of gun sights, for instrument illumination, and for interior communication and fire control applications. Type GF transformers are intended for use in gun, torpedo, rocket, and depth charge firing systems. Type PR transformers are intended for use as anode transformers, interphase transformers, cathode transformers, and auxiliary transformers for power rectifiers. Type TF transformers are intended for use in isolation of grounds in torpedo firing circuits. Type SA transformers are intended for use as internal components of equipment and having performance characteristics, mounting and size most suited for the specific application.
languageEnglish
titleMIL-T-16315Dnum
titleTRANSFORMERS, POWER, STEP-DOWN (MISCELLANEOUS, NAVAL SHIPBOARD USE)en
typestandard
page18
statusActive
treeNAVY - SH - Naval Sea Systems Command (Ship Systems):;1994
contenttypefulltext
subject keywordsMagnet wire
subject keywordsMegohms
subject keywordsRating
subject keywordsVolt-ampere output
subject keywordsVoltmeter
subject keywordsWindings