NASA-LLIS-1398

Lessons Learned – SWIFT Power Control Board Harness Wire Reversal

Organization:
NASA - National Aeronautics and Space Administration (NASA)
Year: 2004

Abstract: Abstract:
Serious damage to an instrument's heater control electronics resulted from incorrect wiring within the interface harness. Efforts to expedite the I&T schedule, incomplete documentation and reduced QA involvement were identified as contributing factors; however, risks were expected to be mitigated by the Safe-to-Mate procedure, which was expected to verify compliance with the ICD. These "time saving" decisions and acceptance of excess risk resulted not only in damage to the instrument but also a 4-month schedule delay.
URI: https://yse.yabesh.ir/std/handle/yse/133557
Subject: Administration/Organization
Collections :
  • NASA - National Aeronautics and Space Administration (NASA)
  • Download PDF : (17.60Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NASA-LLIS-1398

Show full item record

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T17:10:03Z
date available2017-09-04T17:10:03Z
date copyright01/02/2004
date issued2004
identifier otherBZVEQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/133557
description abstractAbstract:
Serious damage to an instrument's heater control electronics resulted from incorrect wiring within the interface harness. Efforts to expedite the I&T schedule, incomplete documentation and reduced QA involvement were identified as contributing factors; however, risks were expected to be mitigated by the Safe-to-Mate procedure, which was expected to verify compliance with the ICD. These "time saving" decisions and acceptance of excess risk resulted not only in damage to the instrument but also a 4-month schedule delay.
languageEnglish
titleNASA-LLIS-1398num
titleLessons Learned – SWIFT Power Control Board Harness Wire Reversalen
typestandard
page4
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;2004
contenttypefulltext
subject keywordsAdministration/Organization
subject keywordsConfiguration Management
subject keywordsHardware
subject keywordsProgram and Project Management
subject keywordsRisk Management/Assessment
subject keywordsSafety & Mission Assurance
subject keywordsSpacecraft
subject keywordsTest & Verification
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian