ASA S1.13

Measurement of Sound Pressure Levels in Ai

Organization:
ASA - Acoustical Society of America
Year: 2010

Abstract: This standard specifies requirements and procedures for the measurement of sound pressure levels in air. These requirements and procedures apply primarily to measurements performed under normal, relatively quiescent meteorological conditions. Nearly all measurements made indoors will fall under such conditions, but outdoor measurements may also be made, and may remain in conformance with this standard provided the ranges of certain environmental variables are restricted, as described herein.
The requirements in this standard (identified by the use of the word shall) are to be understood as conditions on the measurements that must be met in order to state that such measurements have been made in conformance with this American National Standard. The guidelines and recommendations (identified by the use of the word should) are to be understood as conditions that will generally improve the accuracy, validity, applicability, documentation, and reporting of the measurement data but that are not mandatory for conformance.
The type of sounds considered by this standard may differ widely in temporal and spectral characteristics. The sound to be measured may be continuous or intermittent; it may be steady, fluctuating, or impulsive; and it may be essentially broad band or contain discrete tones or narrow bands of noise.
The frequency range covered by the requirements of this standard depends on the specific type of sound level meter or instrumentation being used, but, in general, the frequency content of the sound being measured should be contained within the range covered by the octave bands having center frequencies from 31.5 Hz to 16.0 kHz. The sound pressure levels of sounds whose energy is concentrated outside of this range may not be measured accurately according to the procedures of this standard.
The sound pressure level descriptors primarily used in this standard are the time-average A-weighted sound level (also called the equivalent-continuous A-weighted sound pressure level) and the A-weighted sound exposure level. The choice of descriptor and the measurement procedures to follow depend on the type of sound, and this standard gives requirements and guidelines governing this choice.
The nature of the sound that is being measured by the procedures of this standard may be considered as either desirable (e.g., music from a symphony orchestra or a signal from an alarm device) or undesirable (e.g., noise from a busy highway or household vacuum cleaner). There is no differentiation as far as the procedures in this standard are concerned.
This standard does not address the measurement of sound pressure levels in environments other than air (such as other gases, liquids, or solids), the measurement of infrasonic or ultrasonic sounds, or (generally) the measurement of sound pressure levels outdoors in nonquiescent conditions.
URI: https://yse.yabesh.ir/std/handle/yse/137775
Collections :
  • ASA - Acoustical Society of America
  • Download PDF : (368.3Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASA S1.13

Show full item record

contributor authorASA - Acoustical Society of America
date accessioned2017-09-04T17:14:21Z
date available2017-09-04T17:14:21Z
date copyright01/01/2005 (R 2010)
date issued2010
identifier otherZAILIBAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/137775
description abstractThis standard specifies requirements and procedures for the measurement of sound pressure levels in air. These requirements and procedures apply primarily to measurements performed under normal, relatively quiescent meteorological conditions. Nearly all measurements made indoors will fall under such conditions, but outdoor measurements may also be made, and may remain in conformance with this standard provided the ranges of certain environmental variables are restricted, as described herein.
The requirements in this standard (identified by the use of the word shall) are to be understood as conditions on the measurements that must be met in order to state that such measurements have been made in conformance with this American National Standard. The guidelines and recommendations (identified by the use of the word should) are to be understood as conditions that will generally improve the accuracy, validity, applicability, documentation, and reporting of the measurement data but that are not mandatory for conformance.
The type of sounds considered by this standard may differ widely in temporal and spectral characteristics. The sound to be measured may be continuous or intermittent; it may be steady, fluctuating, or impulsive; and it may be essentially broad band or contain discrete tones or narrow bands of noise.
The frequency range covered by the requirements of this standard depends on the specific type of sound level meter or instrumentation being used, but, in general, the frequency content of the sound being measured should be contained within the range covered by the octave bands having center frequencies from 31.5 Hz to 16.0 kHz. The sound pressure levels of sounds whose energy is concentrated outside of this range may not be measured accurately according to the procedures of this standard.
The sound pressure level descriptors primarily used in this standard are the time-average A-weighted sound level (also called the equivalent-continuous A-weighted sound pressure level) and the A-weighted sound exposure level. The choice of descriptor and the measurement procedures to follow depend on the type of sound, and this standard gives requirements and guidelines governing this choice.
The nature of the sound that is being measured by the procedures of this standard may be considered as either desirable (e.g., music from a symphony orchestra or a signal from an alarm device) or undesirable (e.g., noise from a busy highway or household vacuum cleaner). There is no differentiation as far as the procedures in this standard are concerned.
This standard does not address the measurement of sound pressure levels in environments other than air (such as other gases, liquids, or solids), the measurement of infrasonic or ultrasonic sounds, or (generally) the measurement of sound pressure levels outdoors in nonquiescent conditions.
languageEnglish
titleASA S1.13num
titleMeasurement of Sound Pressure Levels in Aien
typestandard
page52
statusActive
treeASA - Acoustical Society of America:;2010
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian