Archive

NASA-LLIS-0009

Lessons Learned - Lubricant Particles Clogging Spacecraft System Filters

Organization:
NASA - National Aeronautics and Space Administration (NASA)
Year: 1991

Abstract: Description of Driving Event:
Low flow rates were observed in the shuttle orbiter freon coolant loops when the temperatures in the radiator panels dropped below minus 60 degrees Farenheit during a mission. An investigation of the problem revealed that the system filters were clogged with teflon particles. The origin of the particles was traced to the krytox fluoropolymer thread lubricant grease used during loop assembly. Corrective actions were taken to remove, clean, and replace the system filters, several valves, a flow proportioning module, and a pump assembly.
URI: https://yse.yabesh.ir/std/handle/yse/137993
Subject: Flight Equipment
Collections :
  • NASA - National Aeronautics and Space Administration (NASA)
  • Download PDF : (12.98Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NASA-LLIS-0009

Show full item record

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T17:14:34Z
date available2017-09-04T17:14:34Z
date copyright06/14/1991
date issued1991
identifier otherZAYCQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/137993
description abstractDescription of Driving Event:
Low flow rates were observed in the shuttle orbiter freon coolant loops when the temperatures in the radiator panels dropped below minus 60 degrees Farenheit during a mission. An investigation of the problem revealed that the system filters were clogged with teflon particles. The origin of the particles was traced to the krytox fluoropolymer thread lubricant grease used during loop assembly. Corrective actions were taken to remove, clean, and replace the system filters, several valves, a flow proportioning module, and a pump assembly.
languageEnglish
titleNASA-LLIS-0009num
titleLessons Learned - Lubricant Particles Clogging Spacecraft System Filtersen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1991
contenttypefulltext
subject keywordsFlight Equipment
subject keywordsLaunch Vehicle
subject keywordsParts Materials & Processes