Division I-A Seismic Design - General Requirements

contributor authorAASHTO - American Association of State Highway and Transportation Officials
date accessioned2017-09-04T17:17:07Z
date available2017-09-04T17:17:07Z
date copyright01/01/2002
date issued2002
identifier otherZHQNBBAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/140569
description abstractAPPLICABILITY OF SPECIFICATIONS: These Specifications are for the design and construction of new bridges to resist the effect of earthquake motions. The provisions apply to bridges of conventional steel and concrete girder and box girder construction with spans not exceeding 500 feet (150 meters). Suspension bridges, cable-stayed bridges, arch type and movable bridges are not covered by these Specifications. Seismic design is usually not required for buried type (culvert) bridges.
The provisions contained in these Specifications are minimum requirements.
No detailed seismic analysis is required for any single span bridge or for any bridge in Seismic Performance Category A. For single span bridges and bridges classified as SPC A (Section 5) the connections must be designed for specified forces and must also meet minimum support length requirements.
languageEnglish
titleAASHTO HB-17 DIVISION I-A SEC 3num
titleDivision I-A Seismic Design - General Requirementsen
typestandard
page6
statusActive
treeAASHTO - American Association of State Highway and Transportation Officials:;2002
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record