• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • UL - UL
  • View Item
  •   YSE
  • Industrial Standards
  • UL - UL
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

UL 1429 BULLETIN

UL Standard for Safety for Pullout Switches - COMMENTS DUE: JULY 28, 2008

Organization:
UL - UL
Year: 2008

Abstract: These requirements cover non-enclosed and enclosed pullout switches of the detachable type.
These requirements cover pullout switches rated 600 V or less, 400 A or less, with or without horsepower ratings, and with or without high-available fault current ratings.
These requirements cover pullout switches mounted in complete enclosure. Such an enclosure may contain meter sockets or neutral assemblies or both.
These requirements also cover enclosed pullout switches intended for use as service equipment.
These requirements cover non-enclosed pullout switches for use as mains and branches in panelboards, switchboards, and the like.
This standard does not cover hinged pullout switches. Such switches are covered in the Standard for Enclosed and Dead-Front Switches, UL 98.
These requirements do not cover enclosed pullout switches containing more than one independent switch which are covered by the Standard for Panelboards, UL 67.
A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire or of electric shock or injury to persons shall be evaluated using appropriate additional component and end-product requirements to maintain the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard does not comply with this standard. Revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.
URI: https://yse.yabesh.ir/std/handle/yse/145561
Collections :
  • UL - UL
  • Download PDF : (16.90Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 1429 BULLETIN

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T17:22:23Z
date available2017-09-04T17:22:23Z
date copyright06/27/2008
date issued2008
identifier otherZVUJGCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/145561
description abstractThese requirements cover non-enclosed and enclosed pullout switches of the detachable type.
These requirements cover pullout switches rated 600 V or less, 400 A or less, with or without horsepower ratings, and with or without high-available fault current ratings.
These requirements cover pullout switches mounted in complete enclosure. Such an enclosure may contain meter sockets or neutral assemblies or both.
These requirements also cover enclosed pullout switches intended for use as service equipment.
These requirements cover non-enclosed pullout switches for use as mains and branches in panelboards, switchboards, and the like.
This standard does not cover hinged pullout switches. Such switches are covered in the Standard for Enclosed and Dead-Front Switches, UL 98.
These requirements do not cover enclosed pullout switches containing more than one independent switch which are covered by the Standard for Panelboards, UL 67.
A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire or of electric shock or injury to persons shall be evaluated using appropriate additional component and end-product requirements to maintain the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard does not comply with this standard. Revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.
languageEnglish
titleUL 1429 BULLETINnum
titleUL Standard for Safety for Pullout Switches - COMMENTS DUE: JULY 28, 2008en
typestandard
page2
statusActive
treeUL - UL:;2008
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian