IEEE 836
Recommended Practice for Precision Centrifuge Testing of Linear Accelerometers
Year: 2009
Abstract: This recommended practice describes the conduct and analysis of precision tests that are to be performed on linear accelerometers using centrifuge techniques. The term "precision," in this context, refers to tests that are conducted to evaluate accelerometer parameters, as opposed to tests conducted to establish environmental survivability only. Evaluation may take the form of determining the coefficients of the accelerometer's model equation, except for bias and scale factor, which are most accurately determined by static multiposition tests. Alternatively, evaluation may establish only that the accelerometer output complies with specific error limit criteria.
Purpose
The principal error sources encountered during precision centrifuge testing of linear accelerometers are described, along with the test practices and data reduction techniques that have been found most efficient in minimizing or compensating for them.
Purpose
The principal error sources encountered during precision centrifuge testing of linear accelerometers are described, along with the test practices and data reduction techniques that have been found most efficient in minimizing or compensating for them.
Subject: accelerometer
Show full item record
| contributor author | IEEE - The Institute of Electrical and Electronics Engineers, Inc. | |
| date accessioned | 2017-09-04T17:27:20Z | |
| date available | 2017-09-04T17:27:20Z | |
| date copyright | 06/17/2009 | |
| date issued | 2009 | |
| identifier other | CMUSOCAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/150498 | |
| description abstract | This recommended practice describes the conduct and analysis of precision tests that are to be performed on linear accelerometers using centrifuge techniques. The term "precision," in this context, refers to tests that are conducted to evaluate accelerometer parameters, as opposed to tests conducted to establish environmental survivability only. Evaluation may take the form of determining the coefficients of the accelerometer's model equation, except for bias and scale factor, which are most accurately determined by static multiposition tests. Alternatively, evaluation may establish only that the accelerometer output complies with specific error limit criteria. Purpose The principal error sources encountered during precision centrifuge testing of linear accelerometers are described, along with the test practices and data reduction techniques that have been found most efficient in minimizing or compensating for them. | |
| language | English | |
| title | IEEE 836 | num |
| title | Recommended Practice for Precision Centrifuge Testing of Linear Accelerometers | en |
| type | standard | |
| page | 122 | |
| status | Active | |
| tree | IEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2009 | |
| contenttype | fulltext | |
| subject keywords | accelerometer | |
| subject keywords | accelerometer test | |
| subject keywords | centrifuge | |
| subject keywords | linear accelerometer |