API RP 2556

Correction Gauge Tables For Incrustation - SECOND EDITION

Organization:
API - American Petroleum Institute
Year: 2013

Abstract: Incrustation is defined, for the purpose of this recommended practice, as any material that adheres to the internal vertical sidewall surfaces of a tank when the tank is otherwise empty.
Incrustation has the same effect on tank capacity as deadwood (anything that displaces liquid inside a tank) and should be treated as such as long as it remains in the tank. The problem of deducting the volume of liquid displaced by incrustation is complicated by two of incrustation's basic and typical characteristics: First, incrustation is difficult to measure, and second, its thickness is usually variable.
Some oils present no incrustation problem, but many others do, usually on a field-wide basis. The error in measurement from any one tank may be slight, but the accumulated error from an entire field or from any one tank over a period of time could be substantial. The error always has the effect of indicating too large a tank capacity; therefore, a receiving carrier cannot be expected to continually absorb the effect of these errors. The method selected to correct the error should depend upon the desired approach to accuracy of measurement.
The tables given in this recommended practice (see Section 4) show the percent of error of measurement caused by varying thicknesses of uniform incrustation in tanks of various sizes. These tables may be used as a guide by the tank owner and the carrier to negotiate an allowance for incrustation. If it is established that incrustation is causing a substantial loss to a carrier or to any other receiver using affected tank gauges as the basis for custody transfer measurement, it is the responsibility of the tank owner to provide a tank that will permit an accurate measurement or to agree to a reasonable adjustment.
URI: https://yse.yabesh.ir/std/handle/yse/153710
Collections :
  • API - American Petroleum Institute
  • Download PDF : (175.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    API RP 2556

Show full item record

contributor authorAPI - American Petroleum Institute
date accessioned2017-09-04T17:30:48Z
date available2017-09-04T17:30:48Z
date copyright1993.08.01 (R 2013)
date issued2013
identifier otherCVPPHFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/153710
description abstractIncrustation is defined, for the purpose of this recommended practice, as any material that adheres to the internal vertical sidewall surfaces of a tank when the tank is otherwise empty.
Incrustation has the same effect on tank capacity as deadwood (anything that displaces liquid inside a tank) and should be treated as such as long as it remains in the tank. The problem of deducting the volume of liquid displaced by incrustation is complicated by two of incrustation's basic and typical characteristics: First, incrustation is difficult to measure, and second, its thickness is usually variable.
Some oils present no incrustation problem, but many others do, usually on a field-wide basis. The error in measurement from any one tank may be slight, but the accumulated error from an entire field or from any one tank over a period of time could be substantial. The error always has the effect of indicating too large a tank capacity; therefore, a receiving carrier cannot be expected to continually absorb the effect of these errors. The method selected to correct the error should depend upon the desired approach to accuracy of measurement.
The tables given in this recommended practice (see Section 4) show the percent of error of measurement caused by varying thicknesses of uniform incrustation in tanks of various sizes. These tables may be used as a guide by the tank owner and the carrier to negotiate an allowance for incrustation. If it is established that incrustation is causing a substantial loss to a carrier or to any other receiver using affected tank gauges as the basis for custody transfer measurement, it is the responsibility of the tank owner to provide a tank that will permit an accurate measurement or to agree to a reasonable adjustment.
languageEnglish
titleAPI RP 2556num
titleCorrection Gauge Tables For Incrustation - SECOND EDITIONen
typestandard
page14
statusActive
treeAPI - American Petroleum Institute:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian