MIL-T-24634

TREADS, COMPOUND-FILLED, FOR INCLINED LADDERS

Organization:
NAVY - SH - Naval Sea Systems Command (Ship Systems)
Year: 1984

Abstract: This specification covers full treads and cap treads which have slip-resistant compound-filled dovetail grooves in extruded aluminum bases.
Treads shall be of the following types, as specified (see 6.2.1):
Type I - Full tread with end plates.
Type IA - Full tread without end plates.
Type II - Cap tread. Intended Use: Compound-filled treads are intended for, but not limited to, all inclined ladders on board ships, including fixed and feathering tread accommodation ladders. Full treads come complete with end plates drilled with standard spaced holes, unless otherwise ordered, for mounting on new inclined ladders or for the replacement of old treads. They are suitable for both interior and exterior applications. The treads may also be used for fixed or feathering tread accommodation ladders. For feathering, treads shall be ordered without end plates. Treads shall not be installed in machinery spaces of U.S. Navy ships or other applications where the use of steel treads are required for resistance to fire damage. Cap treads do not have end plates but are drilled for mounting, without modification, over existing worn treads which are no more than ⅜ inch wider than the nominal size. Cap treads may also be used for new installations when installed over steel channel sub-bases as in U.S. Navy ship machinery spaces, or aluminum channel sub-bases. They are suitable for both interior and exterior applications if adequate precautions are taken for the treatment of faying surfaces of dissimilar metals.
URI: https://yse.yabesh.ir/std/handle/yse/154116
Collections :
  • NAVY - SH - Naval Sea Systems Command (Ship Systems)
  • Download PDF : (798.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    MIL-T-24634

Show full item record

contributor authorNAVY - SH - Naval Sea Systems Command (Ship Systems)
date accessioned2017-09-04T17:31:10Z
date available2017-09-04T17:31:10Z
date copyright07/25/1984
date issued1984
identifier otherCWTLDAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/154116
description abstractThis specification covers full treads and cap treads which have slip-resistant compound-filled dovetail grooves in extruded aluminum bases.
Treads shall be of the following types, as specified (see 6.2.1):
Type I - Full tread with end plates.
Type IA - Full tread without end plates.
Type II - Cap tread. Intended Use: Compound-filled treads are intended for, but not limited to, all inclined ladders on board ships, including fixed and feathering tread accommodation ladders. Full treads come complete with end plates drilled with standard spaced holes, unless otherwise ordered, for mounting on new inclined ladders or for the replacement of old treads. They are suitable for both interior and exterior applications. The treads may also be used for fixed or feathering tread accommodation ladders. For feathering, treads shall be ordered without end plates. Treads shall not be installed in machinery spaces of U.S. Navy ships or other applications where the use of steel treads are required for resistance to fire damage. Cap treads do not have end plates but are drilled for mounting, without modification, over existing worn treads which are no more than ⅜ inch wider than the nominal size. Cap treads may also be used for new installations when installed over steel channel sub-bases as in U.S. Navy ship machinery spaces, or aluminum channel sub-bases. They are suitable for both interior and exterior applications if adequate precautions are taken for the treatment of faying surfaces of dissimilar metals.
languageEnglish
titleMIL-T-24634num
titleTREADS, COMPOUND-FILLED, FOR INCLINED LADDERSen
typestandard
page19
statusActive
treeNAVY - SH - Naval Sea Systems Command (Ship Systems):;1984
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian