Show simple item record

INSULATION CLOTH AND TAPE, ELECTRICAL, VARNISHED CAMBRIC

contributor authorNAVY - SH - Naval Sea Systems Command (Ship Systems)
date accessioned2017-09-04T15:16:19Z
date available2017-09-04T15:16:19Z
date copyright07/25/1955
date issued1955
identifier otherMJGIDAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/15544
description abstractThis specification covers insurance intended for use as cable insulation, coil wrappers, and for insulating bus bars, joints and terminals of electric wires and cables winding insulation and other electrical apparatus connection.
Insulation shall be of the following types and classes, as specified (see 6.2):
     Type I-Cloth        Class 1-Bias cut        Class 2-Straight cut      Type II-Tape        Class 1-Bias cut        Class 2-Straight cut


Intended Use: Type I, class 2 and Type II, class 1 insulation, covered by this specification, are intended for repair and maintenance. Type I, class 1 and Type II, class 2 insulations are intended to be utilized by contractors as a component of their finished products, and should not be ordered as a stock item.
languageEnglish
titleMIL-I-3374Anum
titleINSULATION CLOTH AND TAPE, ELECTRICAL, VARNISHED CAMBRICen
typestandard
page8
statusActive
treeNAVY - SH - Naval Sea Systems Command (Ship Systems):;1955
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)