• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

IEEE 1142

Guide for the Selection, Testing, Application, and Installation of Cables having Radial-Moisture Barriers and/or Longitudianal Water Blocking

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2009

Abstract: This guide provides cable manufacturers and users with extensive information on the design, testing, application, and installation of low, medium, and high-voltage power cables, as well as communication, control and instrument cables that make use of metal-plastic laminates as radial-moisture barriers. This guide addresses additional means of protecting cables from the entrance of moisture through the use of polymeric super absorbent materials for longitudinal water blocking of stranded conductors and other spaces within cables. The alternate use of extruded metal sheaths or bare, longitudinally applied, metallic tapes with sealed seams will likewise be addressed.
Purpose
While metallic sheaths, such as lead and aluminum, have been effective in past years as barriers to moisture, their relative cost, environmental concerns along with installation difficulties have led to the search for alternatives. Alternatively, thin metal-plastic foils are finding application as moisture barriers in low, medium, high, and extra-high voltage power cables. Aluminum, copper, or lead substrates are coated with polymeric coatings on one or both sides and adhesively bonded to the cable jacket or over sheath. The tapes are usually applied longitudinally, with an overlap, or seam, that is adhesively sealed over the core of the cable and under the jacket. In addition, other measures have been taken to block the longitudinal movement of moisture through the conductor and the shield interfaces so that water-impervious cables are now available. This guide will provide information on the use of such coated metals in cable constructions as well as the use of other materials for longitudinal water blocking. Cable users should find this information of value in the selection, specification, installation, and testing of cables having radial-moisture barriers and/or longitudinal water-blocking systems.
There is an extensive amount of information in this guide that refers to IEC Standards, British Standards and CIGRE study group recommendations. These organizations, and others, have developed recommendations, standards and specifications that are pertinent to cables with radial-moisture barriers and longitudinal water blocking. Inclusion of a discussion of these documents presents the user of the guide with a more complete picture of the degree to which cables with radial and longitudinal moisture protection have developed. The technology has matured greatly since this guide was first published and inclusion of all pertinent information not only serves to better inform the user of the guide but also documents how extensive and prevalent the technology has become globally.
URI: https://yse.yabesh.ir/std/handle/yse/159003
Subject: laminate sheaths
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (905.3Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE 1142

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T17:36:07Z
date available2017-09-04T17:36:07Z
date copyright40156
date issued2009
identifier otherDJTHSCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/159003
description abstractThis guide provides cable manufacturers and users with extensive information on the design, testing, application, and installation of low, medium, and high-voltage power cables, as well as communication, control and instrument cables that make use of metal-plastic laminates as radial-moisture barriers. This guide addresses additional means of protecting cables from the entrance of moisture through the use of polymeric super absorbent materials for longitudinal water blocking of stranded conductors and other spaces within cables. The alternate use of extruded metal sheaths or bare, longitudinally applied, metallic tapes with sealed seams will likewise be addressed.
Purpose
While metallic sheaths, such as lead and aluminum, have been effective in past years as barriers to moisture, their relative cost, environmental concerns along with installation difficulties have led to the search for alternatives. Alternatively, thin metal-plastic foils are finding application as moisture barriers in low, medium, high, and extra-high voltage power cables. Aluminum, copper, or lead substrates are coated with polymeric coatings on one or both sides and adhesively bonded to the cable jacket or over sheath. The tapes are usually applied longitudinally, with an overlap, or seam, that is adhesively sealed over the core of the cable and under the jacket. In addition, other measures have been taken to block the longitudinal movement of moisture through the conductor and the shield interfaces so that water-impervious cables are now available. This guide will provide information on the use of such coated metals in cable constructions as well as the use of other materials for longitudinal water blocking. Cable users should find this information of value in the selection, specification, installation, and testing of cables having radial-moisture barriers and/or longitudinal water-blocking systems.
There is an extensive amount of information in this guide that refers to IEC Standards, British Standards and CIGRE study group recommendations. These organizations, and others, have developed recommendations, standards and specifications that are pertinent to cables with radial-moisture barriers and longitudinal water blocking. Inclusion of a discussion of these documents presents the user of the guide with a more complete picture of the degree to which cables with radial and longitudinal moisture protection have developed. The technology has matured greatly since this guide was first published and inclusion of all pertinent information not only serves to better inform the user of the guide but also documents how extensive and prevalent the technology has become globally.
languageEnglish
titleIEEE 1142num
titleGuide for the Selection, Testing, Application, and Installation of Cables having Radial-Moisture Barriers and/or Longitudianal Water Blockingen
typestandard
page72
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2009
contenttypefulltext
subject keywordslaminate sheaths
subject keywordslongitudinal water blocking
subject keywordsmoisture impervious
subject keywordspowders
subject keywordsradialmoisture barriers
subject keywordssealed overlap
subject keywordswater-swellable tapes
subject keywordsyarns
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian