IEEE C37.20.7 INT 1

Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2009

Abstract: Scope:

This guide establishes a method by which metal-enclosed switchgear, as defined by IEEE Std C37.20.2-1999 and IEEE Std C37.20.3-2001, can be tested for resistance to the effects of arcing due to an internal fault. This guide applies only to equipment utilizing air as the primary insulating medium and rated above 1000 V ac. It applies to both indoor and outdoor equipment; however, special consideration must be given to the building size and construction for indoor applications (not addressed by this guide).

The tests and assessments described in this guide are only applicable to arcing faults occurring entirely in air within the enclosure when all doors and covers are properly secured. This guide does not apply to arcing faults that occur within a component of the switchgear assembly, such as instrument transformers, sealed interrupting devices, fuses, etc.

Switchgear designs that meet the requirements of this guide will be referred to as arc-resistant metal-enclosed interrupter switchgear or arc-resistant metal-clad switchgear as applicable, or, generally, as arc-resistant switchgear.

URI: https://yse.yabesh.ir/std/handle/yse/160493
Subject: accessibility
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (47.34Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE C37.20.7 INT 1

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T17:37:37Z
date available2017-09-04T17:37:37Z
date copyright40118
date issued2009
identifier otherDNOKPCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/160493
description abstractScope:

This guide establishes a method by which metal-enclosed switchgear, as defined by IEEE Std C37.20.2-1999 and IEEE Std C37.20.3-2001, can be tested for resistance to the effects of arcing due to an internal fault. This guide applies only to equipment utilizing air as the primary insulating medium and rated above 1000 V ac. It applies to both indoor and outdoor equipment; however, special consideration must be given to the building size and construction for indoor applications (not addressed by this guide).

The tests and assessments described in this guide are only applicable to arcing faults occurring entirely in air within the enclosure when all doors and covers are properly secured. This guide does not apply to arcing faults that occur within a component of the switchgear assembly, such as instrument transformers, sealed interrupting devices, fuses, etc.

Switchgear designs that meet the requirements of this guide will be referred to as arc-resistant metal-enclosed interrupter switchgear or arc-resistant metal-clad switchgear as applicable, or, generally, as arc-resistant switchgear.

languageEnglish
titleIEEE C37.20.7 INT 1num
titleGuide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faultsen
typestandard
page3
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2009
contenttypefulltext
subject keywordsaccessibility
subject keywordsarc
subject keywordsbus
subject keywordscompartment
subject keywordsinternal arcing fault
subject keywordsmetal-clad switchgear
subject keywordsmetal-enclosed interrupter switchgear
subject keywordsmetal-enclosed switchgear
subject keywordsoverpressure
subject keywordsprotection