ASHRAE QC-06-045

Air Distribution in a Room with Ceiling-Mounted Diffusers - Comparison with Wall-Mounted Diffuser, Vertical Ventilation, and Displacement Ventilation

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2006

Abstract: Experiments with room air distribution that is generated by a radial ceiling-mounted diffuser and a diffuser generating flow with swirl are compared with the air distribution obtained by mixing ventilation from a wall-mounted diffuser, vertical ventilation, and displacement ventilation. The air distribution generated by a radial diffuser is partly controlled by the momentum flow from the diffusers and partly from gravity forces where the thermal load and the temperature difference between room air and supply air deflect the radial wall jet down into the occupied zone. The ceiling diffuser with swirling flow generates a flow pattern in the room that is rater uninfluenced by the thermal load. The flow is highly mixed above the occupied zone, and the air movement penetrates the occupied zone close to the walls.
All systems were tested in the same room with a load consisting of two manikins, each sitting at a desk with two PCs and two desk lamps, producing a total heat load of 480 W.
In all five cases, the design of the air distribution system was based on flow elements from the diffuser, a maximum velocity assumption, and a critical vertical temperature gradient in the room. The characteristics of the air distribution systems are addressed by analyzing the acceptable conditions for the supply flow rate and the temperature difference for the different systems.
This paper shows that an air distribution system with ceiling-mounted air terminal units is able to generate comfortable velocity and temperature conditions at the same and at slightly higher loads as can be obtained by a vertical ventilation system, a mixing ventilation system with wall-mounted diffuser, and a displacement ventilation system with a low-velocity wall-mounted diffuser.
The comparison is extended by considering both the local discomfort caused y draft and the percentage of dissatisfied due to the temperature gradient when this is relevant to the systems. The draft rating is low for the ceiling-mounted diffusers as well as for the low impulse system (textile terminals), and the temperature gradient is also low because of the high level of room air mixing.
URI: https://yse.yabesh.ir/std/handle/yse/165090
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (573.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE QC-06-045

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T17:42:03Z
date available2017-09-04T17:42:03Z
date copyright01/01/2006
date issued2006
identifier otherDZRQJBAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/165090
description abstractExperiments with room air distribution that is generated by a radial ceiling-mounted diffuser and a diffuser generating flow with swirl are compared with the air distribution obtained by mixing ventilation from a wall-mounted diffuser, vertical ventilation, and displacement ventilation. The air distribution generated by a radial diffuser is partly controlled by the momentum flow from the diffusers and partly from gravity forces where the thermal load and the temperature difference between room air and supply air deflect the radial wall jet down into the occupied zone. The ceiling diffuser with swirling flow generates a flow pattern in the room that is rater uninfluenced by the thermal load. The flow is highly mixed above the occupied zone, and the air movement penetrates the occupied zone close to the walls.
All systems were tested in the same room with a load consisting of two manikins, each sitting at a desk with two PCs and two desk lamps, producing a total heat load of 480 W.
In all five cases, the design of the air distribution system was based on flow elements from the diffuser, a maximum velocity assumption, and a critical vertical temperature gradient in the room. The characteristics of the air distribution systems are addressed by analyzing the acceptable conditions for the supply flow rate and the temperature difference for the different systems.
This paper shows that an air distribution system with ceiling-mounted air terminal units is able to generate comfortable velocity and temperature conditions at the same and at slightly higher loads as can be obtained by a vertical ventilation system, a mixing ventilation system with wall-mounted diffuser, and a displacement ventilation system with a low-velocity wall-mounted diffuser.
The comparison is extended by considering both the local discomfort caused y draft and the percentage of dissatisfied due to the temperature gradient when this is relevant to the systems. The draft rating is low for the ceiling-mounted diffusers as well as for the low impulse system (textile terminals), and the temperature gradient is also low because of the high level of room air mixing.
languageEnglish
titleASHRAE QC-06-045num
titleAir Distribution in a Room with Ceiling-Mounted Diffusers - Comparison with Wall-Mounted Diffuser, Vertical Ventilation, and Displacement Ventilationen
typestandard
page7
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2006
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian