CSA CAN/CSA-E60730-2-10:13

English -- Automatic electrical controls for household and similar use - Part 2-10: Particular requirements for motor-starting relays - Second Edition;
French -- Dispositifs de commande électrique automatiques à usage domestique et analogue - Partie 2-10 : Règles particulières pour les relais électriques de démarrage de moteur - Second Edition

Organization:
CSA - CSA Group
Year: 2013

Abstract: This part of IEC 60730 applies to controls for automatically controlling the starting windings of single phase motors associated with equipment for household and similar use.
This standard applies to motor-starting relays using NTC or PTC thermistors, additional requirements for which are contained in Annex J.
This standard applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety, and to the testing of motor-starting relays used in, or in association with, household or similar equipment.
Motor-starting relays for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.
This standard does not apply to motor-starting relays designed exclusively for industrial applications.
Throughout this standard, the word "equipment" means "appliance and equipment". The words "starting relay" mean "motor-starting relay".
This standard applies to starting relays incorporating electronic devices and starting relays using thermistor elements, thermal elements and magnetic elements.
This standard does not apply to general purpose relays or to contactors and motor starters of the type covered by the IEC 60947 series1. This standard does not apply to mechanical timers or mechanically operated motor-starting devices.
This standard applies to manual controls when such are electrically and/or mechanically integral with starting
Requirements for manual switches not forming part of a starting relay are contained in IEC 61058-1.
1 IEC 60947 (all parts), Low-voltage switchgear and controlgear
URI: https://yse.yabesh.ir/std/handle/yse/165458
Collections :
  • CSA - CSA Group
  • Download PDF : (2.411Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA CAN/CSA-E60730-2-10:13

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T17:42:25Z
date available2017-09-04T17:42:25Z
date copyright2013.03.01
date issued2013
identifier otherEARJDFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/165458
description abstractThis part of IEC 60730 applies to controls for automatically controlling the starting windings of single phase motors associated with equipment for household and similar use.
This standard applies to motor-starting relays using NTC or PTC thermistors, additional requirements for which are contained in Annex J.
This standard applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety, and to the testing of motor-starting relays used in, or in association with, household or similar equipment.
Motor-starting relays for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.
This standard does not apply to motor-starting relays designed exclusively for industrial applications.
Throughout this standard, the word "equipment" means "appliance and equipment". The words "starting relay" mean "motor-starting relay".
This standard applies to starting relays incorporating electronic devices and starting relays using thermistor elements, thermal elements and magnetic elements.
This standard does not apply to general purpose relays or to contactors and motor starters of the type covered by the IEC 60947 series1. This standard does not apply to mechanical timers or mechanically operated motor-starting devices.
This standard applies to manual controls when such are electrically and/or mechanically integral with starting
Requirements for manual switches not forming part of a starting relay are contained in IEC 61058-1.
1 IEC 60947 (all parts), Low-voltage switchgear and controlgear
languageEnglish, French
titleCSA CAN/CSA-E60730-2-10:13num
titleEnglish -- Automatic electrical controls for household and similar use - Part 2-10: Particular requirements for motor-starting relays - Second Editionen
titleFrench -- Dispositifs de commande électrique automatiques à usage domestique et analogue - Partie 2-10 : Règles particulières pour les relais électriques de démarrage de moteur - Second Editionother
typestandard
page44
statusActive
treeCSA - CSA Group:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian