DSCC-DWG-88055 REV D

FILTER, ASSEMBLY, ELECTRICAL

Organization:
DLA - CC - DLA Land and Maritime
Year: 2006

Abstract: This drawing describes the requirements for a filter assembly consisting of two capacitors and a choke. The filter assembly is used in a line voltage regulator; type SPR-400, 26 KVA 115 V/115 V, 400 Hz, single phase and is intended to reject the third harmonic (1,200 Hz). Units are tested together but are shipped as a kit consisting of the three separate parts.Intended Use: This filter assembly is used in a line voltage regulator; type SPR-400, 26 KVA 115 V/115 V, 400 Hz, single phase and is intended to reject the third harmonic (1,200 Hz). 
URI: https://yse.yabesh.ir/std/handle/yse/166921
Collections :
  • DLA - CC - DLA Land and Maritime
  • Download PDF : (89.31Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    DSCC-DWG-88055 REV D

Show full item record

contributor authorDLA - CC - DLA Land and Maritime
date accessioned2017-09-04T17:43:49Z
date available2017-09-04T17:43:49Z
date copyright08/28/2006
date issued2006
identifier otherEEPPJBAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/166921
description abstractThis drawing describes the requirements for a filter assembly consisting of two capacitors and a choke. The filter assembly is used in a line voltage regulator; type SPR-400, 26 KVA 115 V/115 V, 400 Hz, single phase and is intended to reject the third harmonic (1,200 Hz). Units are tested together but are shipped as a kit consisting of the three separate parts.Intended Use: This filter assembly is used in a line voltage regulator; type SPR-400, 26 KVA 115 V/115 V, 400 Hz, single phase and is intended to reject the third harmonic (1,200 Hz). 
languageEnglish
titleDSCC-DWG-88055 REV Dnum
titleFILTER, ASSEMBLY, ELECTRICALen
typestandard
page10
statusActive
treeDLA - CC - DLA Land and Maritime:;2006
contenttypefulltext