ASHRAE LV-11-006

Capture and Containment Ventilation Rates for Single-Island Canopy Hoods

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2011

Abstract: ABSTRACT
The objective of ASHRAE 1480-RP was to expand the database for the capture and containment requirements of island canopy hoods. The study investigated the performance of four 10 ft long (3.05 m) island canopy hood configurations over standardized cooking equipment lines including: (1) a 4 ft (1.22 m) deep rear filter single-island, (2) a 6 ft (1.83 m) deep V-bank single-island, (3) an 8 ft (2.44 m) deep double-island, and (4) a 10 ft (3.05 m) deep double-island hood. More than 200 configurations were tested, including the evaluation of side panels, replacement air strategies, and replacement air temperatures. This paper provides an overview of the capture and containment performance for the two single-island canopy hoods. It was found that large appliance overhangs and wellbalanced, low-velocity replacement air were critical for the optimization of single-island canopy hood performance.
URI: https://yse.yabesh.ir/std/handle/yse/170366
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (13.03Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE LV-11-006

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T17:47:06Z
date available2017-09-04T17:47:06Z
date copyright01/01/2011
date issued2011
identifier otherENXTKEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/170366
description abstractABSTRACT
The objective of ASHRAE 1480-RP was to expand the database for the capture and containment requirements of island canopy hoods. The study investigated the performance of four 10 ft long (3.05 m) island canopy hood configurations over standardized cooking equipment lines including: (1) a 4 ft (1.22 m) deep rear filter single-island, (2) a 6 ft (1.83 m) deep V-bank single-island, (3) an 8 ft (2.44 m) deep double-island, and (4) a 10 ft (3.05 m) deep double-island hood. More than 200 configurations were tested, including the evaluation of side panels, replacement air strategies, and replacement air temperatures. This paper provides an overview of the capture and containment performance for the two single-island canopy hoods. It was found that large appliance overhangs and wellbalanced, low-velocity replacement air were critical for the optimization of single-island canopy hood performance.
languageEnglish
titleASHRAE LV-11-006num
titleCapture and Containment Ventilation Rates for Single-Island Canopy Hoodsen
typestandard
page13
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian