Now showing items 841-860 of 2692

    • ASHRAE OR-16-C083 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: As zero net energy (ZNE) and other low-energy buildings become increasingly common, it is important to consider how different ZNE strategies can interact with local electricity grids. The electricity ...
    • ASHRAE 52.2 ADD E 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: FOREWORD
      This addendum addresses concerns regarding partial, shortcut, or initial testing only that can misstate the MERV performance classification and discredit the validity of the minimum reporting ...
    • ASHRAE APPLICATION SI CH 52 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE HVAC APPLICATIONS SI CH 8 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2015
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE LV-11-026 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: ABSTRACT
      Under a real-time pricing rate structure, the focus of operating a chilled-water storage system is to determine the optimal starting and ending time of charging and discharging the tank. ...
    • ASHRAE AN-04-10 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2004
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE NY-08-046 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2008
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE 40 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2006
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: This standard applies to heat-operated unitary air conditioners and heat pumps consisting of one or more assemblies, including engine-driven systems. Where such equipment is provided in more than one assembly, the separate ...
    • ASHRAE REFRIGERATION SI CH 48 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2010
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE OR-16-C057 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: California's single-family residential building stock is dominated by gas-fired storage water heaters. This is a result of the building energy efficiency code. For decades the water heater energy consumption calculated ...
    • ASHRAE QC-06-016 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2006
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE SYSTEMS AND EQUIP SI CH 44 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2012
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE APPLICATION IP CH 31 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE HVAC APPLICATIONS IP CH 48 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2015
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE NA-04-4-1 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2004
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: Raised-floor data centers are commonly used to house computer servers, telecommunications equipment, and data storage systems. The equipment dissipates a significant amount of heat and must be maintained at acceptable ...
    • ASHRAE AB-10-002 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2010
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: INTRODUCTION
      Corrugated spiral ducts are increasingly being used in aboveground HVAC systems. The presence of corrugations increases the rigidity and structural strength of the duct, so that lighter ...
    • ASHRAE 90.1-2013 I-P ERTA 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2014
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE GUIDELINE 29 ADD A 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2009
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: This standard prescribes the methods of testing automatic ice makers.
      The automatic ice maker may comprise one or more sections for shipping purposes.
      This standard does not include automatic ice makers installed ...
    • ASHRAE NA-04-2-5 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2004
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE NY-08-019 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2008
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.