ASHRAE NA-04-4-1

Distribution of Cooling Airflow in a Raised-Floor Data Cente

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2004

Abstract: Raised-floor data centers are commonly used to house computer servers, telecommunications equipment, and data storage systems. The equipment dissipates a significant amount of heat and must be maintained at acceptable temperatures for reliable operation. It is not sufficient that the data center as a whole receives the required amount of cooling air. Each piece of equipment must be given the amount of cooling air that corresponds to its heat load. Therefore, special attention must be paid to the distribution of cooling air in the data center.
This paper uses the fluid mechanics of the underfloor space to calculate the distribution of the airflow rate through the perforated tiles. The effect of different factors such as the floor height and the open area of the perforated tiles is discussed.
URI: https://yse.yabesh.ir/std/handle/yse/189588
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (555.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE NA-04-4-1

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T18:06:40Z
date available2017-09-04T18:06:40Z
date copyright01/01/2004
date issued2004
identifier otherGMXWGBAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/189588
description abstractRaised-floor data centers are commonly used to house computer servers, telecommunications equipment, and data storage systems. The equipment dissipates a significant amount of heat and must be maintained at acceptable temperatures for reliable operation. It is not sufficient that the data center as a whole receives the required amount of cooling air. Each piece of equipment must be given the amount of cooling air that corresponds to its heat load. Therefore, special attention must be paid to the distribution of cooling air in the data center.
This paper uses the fluid mechanics of the underfloor space to calculate the distribution of the airflow rate through the perforated tiles. The effect of different factors such as the floor height and the open area of the perforated tiles is discussed.
languageEnglish
titleASHRAE NA-04-4-1num
titleDistribution of Cooling Airflow in a Raised-Floor Data Centeen
typestandard
page6
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2004
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian