CSA C22.2 NO. 206-13

Lighting Poles - Second Edition

Organization:
CSA - CSA Group
Year: 2013

Abstract: This Standard applies to free-standing poles of ferrous metal, aluminum, polymeric, concrete, and wood, and to their accessories, for use in the support of lighting equipment having ratings of 600 V and less, and intended to be installed in the commercial and industrial nonhazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I.
This Standard applies to poles used for the support of lighting equipment, such as luminaires, electric signs, and traffic lights. The poles may also serve as supports for aerial conductors, PV modules, and wind turbines used to supply the lighting equipment and, in the case of concrete or metal poles, provide wireways for conductors entering the poles.
This Standard applies to the electrical features of poles as well as to the mechanical strength aspects and the ability to support their design loads.
This Standard does not apply to the erection of poles or the installation of accessories on site.
Note: Lighting Poles for residential applications less than 4 m in height may be evaluated to the requirements of CSA C22.2 No 250.0 for electrical safety only, and be marked NOT EVALUATED FOR STRUCTURAL STRENGTH.
General requirements applicable to this Standard are given in CAN/CSA-C22.2 No. 0.
In CSA Group Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
URI: https://yse.yabesh.ir/std/handle/yse/171510
Collections :
  • CSA - CSA Group
  • Download PDF : (1.146Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA C22.2 NO. 206-13

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T17:48:20Z
date available2017-09-04T17:48:20Z
date copyright2013.03.01
date issued2013
identifier otherEQUODFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/171510
description abstractThis Standard applies to free-standing poles of ferrous metal, aluminum, polymeric, concrete, and wood, and to their accessories, for use in the support of lighting equipment having ratings of 600 V and less, and intended to be installed in the commercial and industrial nonhazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I.
This Standard applies to poles used for the support of lighting equipment, such as luminaires, electric signs, and traffic lights. The poles may also serve as supports for aerial conductors, PV modules, and wind turbines used to supply the lighting equipment and, in the case of concrete or metal poles, provide wireways for conductors entering the poles.
This Standard applies to the electrical features of poles as well as to the mechanical strength aspects and the ability to support their design loads.
This Standard does not apply to the erection of poles or the installation of accessories on site.
Note: Lighting Poles for residential applications less than 4 m in height may be evaluated to the requirements of CSA C22.2 No 250.0 for electrical safety only, and be marked NOT EVALUATED FOR STRUCTURAL STRENGTH.
General requirements applicable to this Standard are given in CAN/CSA-C22.2 No. 0.
In CSA Group Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
languageEnglish
titleCSA C22.2 NO. 206-13num
titleLighting Poles - Second Editionen
typestandard
page33
statusActive
treeCSA - CSA Group:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian