• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • UL - UL
  • View Item
  •   YSE
  • Industrial Standards
  • UL - UL
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

UL SUBJECT 2748

UL Outline for Investigation Arcing Fault Quenching Equipment - Issue 3

Organization:
UL - UL
Year: 2015

Abstract: These requirements cover equipment intended to quench arcing faults by creating a lower impedance current path, located within a controlled compartment, to cause the arcing fault to transfer to the new current path.
These requirements cover equipment that may either be completely enclosed units or intended to be installed within power distribution equipment.
These requirements cover equipment rated up to 38 kV ac maximum.
This outline does not include the requirements for sensors intended to detect arcing fault, devices intended to trigger the functioning of the arc quenching equipment, or devices that are intended to interrupt arcing fault currents.
This outline does not include all the requirements for integration and testing of arc quenching equipment within equipment it is intended to protect.
URI: https://yse.yabesh.ir/std/handle/yse/172282
Collections :
  • UL - UL
  • Download PDF : (45.53Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL SUBJECT 2748

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T17:49:04Z
date available2017-09-04T17:49:04Z
date copyright2015.11.03
date issued2015
identifier otherESYQMFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/172282
description abstractThese requirements cover equipment intended to quench arcing faults by creating a lower impedance current path, located within a controlled compartment, to cause the arcing fault to transfer to the new current path.
These requirements cover equipment that may either be completely enclosed units or intended to be installed within power distribution equipment.
These requirements cover equipment rated up to 38 kV ac maximum.
This outline does not include the requirements for sensors intended to detect arcing fault, devices intended to trigger the functioning of the arc quenching equipment, or devices that are intended to interrupt arcing fault currents.
This outline does not include all the requirements for integration and testing of arc quenching equipment within equipment it is intended to protect.
languageEnglish
titleUL SUBJECT 2748num
titleUL Outline for Investigation Arcing Fault Quenching Equipment - Issue 3en
typestandard
page14
statusActive
treeUL - UL:;2015
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian