ASHRAE LV-11-C061

Application Issues for Chilled Beam Technologies

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2011

Abstract: ABSTRACT
Recently, many discussions and papers relating to chilled beams have been published. Chilled beams usage has become rampant along with Dedicated Outside Air Systems (DOAS). The paper discusses the design issues relating to filtration, induction effect, certification and energy consumption. In most cases, only the energy savings relating to reduced air qualities may not be real. The paper discusses the application issues for chilled beam technologies, its usages and cost effectiveness.
URI: https://yse.yabesh.ir/std/handle/yse/173745
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (1.737Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE LV-11-C061

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T17:50:33Z
date available2017-09-04T17:50:33Z
date copyright01/01/2011
date issued2011
identifier otherEWXTKEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/173745
description abstractABSTRACT
Recently, many discussions and papers relating to chilled beams have been published. Chilled beams usage has become rampant along with Dedicated Outside Air Systems (DOAS). The paper discusses the design issues relating to filtration, induction effect, certification and energy consumption. In most cases, only the energy savings relating to reduced air qualities may not be real. The paper discusses the application issues for chilled beam technologies, its usages and cost effectiveness.
languageEnglish
titleASHRAE LV-11-C061num
titleApplication Issues for Chilled Beam Technologiesen
typestandard
page8
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian