IEEE 1159

Recommended Practice for Monitoring Electric Power Quality

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2009

Abstract: This recommended practice encompasses the monitoring of electrical characteristics of single-phase and polyphase ac power systems. It includes consistent descriptions of conducted electromagnetic phenomena occurring on power systems. This recommended practice presents definitions of nominal conditions and deviations from these nominal conditions that may originate within the source of supply or load equipment or may originate from interactions between the source and the load. Also, this recommended practice discusses measurement techniques, application techniques, and the interpretation of monitoring results.
Purpose
The use of equipment that causes and is susceptible to various electromagnetic phenomena has heightened the interest in power quality. An increase in operational problems has led to a variety of attempts to describe the phenomena. Because different segments of the technical community have used different terminologies to describe these electromagnetic events, this recommended practice provides users with a consistent set of terms and definitions for describing these events. An understanding of how power quality events impact the power system and end-use equipment is required in order to make monitoring useful. Proper measuring techniques are required to safely obtain useful, accurate data. Appropriate location of monitors, systematic studies, and interpretation of results will enhance the value of power quality monitoring. The purpose of this recommended practice is to assist users as well as equipment and software manufacturers and vendors by describing techniques for defining, measuring, quantifying, and interpreting electromagnetic disturbances on the power system.
URI: https://yse.yabesh.ir/std/handle/yse/177203
Subject: assessment
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (1.269Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE 1159

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T17:54:04Z
date available2017-09-04T17:54:04Z
date copyright03/18/2009
date issued2009
identifier otherFGESPCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/177203
description abstractThis recommended practice encompasses the monitoring of electrical characteristics of single-phase and polyphase ac power systems. It includes consistent descriptions of conducted electromagnetic phenomena occurring on power systems. This recommended practice presents definitions of nominal conditions and deviations from these nominal conditions that may originate within the source of supply or load equipment or may originate from interactions between the source and the load. Also, this recommended practice discusses measurement techniques, application techniques, and the interpretation of monitoring results.
Purpose
The use of equipment that causes and is susceptible to various electromagnetic phenomena has heightened the interest in power quality. An increase in operational problems has led to a variety of attempts to describe the phenomena. Because different segments of the technical community have used different terminologies to describe these electromagnetic events, this recommended practice provides users with a consistent set of terms and definitions for describing these events. An understanding of how power quality events impact the power system and end-use equipment is required in order to make monitoring useful. Proper measuring techniques are required to safely obtain useful, accurate data. Appropriate location of monitors, systematic studies, and interpretation of results will enhance the value of power quality monitoring. The purpose of this recommended practice is to assist users as well as equipment and software manufacturers and vendors by describing techniques for defining, measuring, quantifying, and interpreting electromagnetic disturbances on the power system.
languageEnglish
titleIEEE 1159num
titleRecommended Practice for Monitoring Electric Power Qualityen
typestandard
page91
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2009
contenttypefulltext
subject keywordsassessment
subject keywordscompatibility
subject keywordsdip
subject keywordsdistortion
subject keywordselectromagnetic phenomena
subject keywordsharmonics
subject keywordsimbalance
subject keywordsinstruments
subject keywordsmonitoring
subject keywordspower quality
subject keywordsrms variation
subject keywordssag
subject keywordsswell
subject keywordstransient
subject keywordsunbalance
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian