Archive

ASHRAE OR-16-C047

Experimental Validation of a Thermal Resistance and Capacity Model for Geothermal Boreholes

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2016

Abstract: Thermal Resistance Capacity (TRC) models are used to account for thermal capacity when simulating geothermal boreholes. One such model is presented in this paper. In the proposed model, the borehole is discretized in the axial direction with a limited number of segments of equal height. The grout capacity at any given cross-section is lumped together in various nodes each with its own temperature. The fluid capacity is also included with two nodes, one for each U-tube leg. Finally, the borehole wall temperature is obtained from a ground heat transfer model based on the classic cylindrical heat source analytical solution. Experimental data from two tests performed at the Canadian Centre for Housing Technology (Ottawa, Canada) are used to validate the TRC model presented here. The first data set is taken from a thermal response test (TRT) performed on a 76 m borehole. This test is used to obtain the ground thermal conductivity but also to calibrate the ground model to estimate the ground thermal diffusivity. The second set is taken from the actual operation of two parallel boreholes linked to two 3.52 kW (1 ton) heat pumps used to heat a house. Measurements were taken every 5 minutes over a period of 47 days and include periods of intermittent operation. Results show that there is excellent agreement between the outlet temperatures and the grout temperatures predicted by the TRC model and the corresponding experimental temperatures.
URI: https://yse.yabesh.ir/std/handle/yse/179798
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (320.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE OR-16-C047

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T17:56:44Z
date available2017-09-04T17:56:44Z
date copyright2016.01.01
date issued2016
identifier otherFMXPOFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/179798
description abstractThermal Resistance Capacity (TRC) models are used to account for thermal capacity when simulating geothermal boreholes. One such model is presented in this paper. In the proposed model, the borehole is discretized in the axial direction with a limited number of segments of equal height. The grout capacity at any given cross-section is lumped together in various nodes each with its own temperature. The fluid capacity is also included with two nodes, one for each U-tube leg. Finally, the borehole wall temperature is obtained from a ground heat transfer model based on the classic cylindrical heat source analytical solution. Experimental data from two tests performed at the Canadian Centre for Housing Technology (Ottawa, Canada) are used to validate the TRC model presented here. The first data set is taken from a thermal response test (TRT) performed on a 76 m borehole. This test is used to obtain the ground thermal conductivity but also to calibrate the ground model to estimate the ground thermal diffusivity. The second set is taken from the actual operation of two parallel boreholes linked to two 3.52 kW (1 ton) heat pumps used to heat a house. Measurements were taken every 5 minutes over a period of 47 days and include periods of intermittent operation. Results show that there is excellent agreement between the outlet temperatures and the grout temperatures predicted by the TRC model and the corresponding experimental temperatures.
languageEnglish
titleASHRAE OR-16-C047num
titleExperimental Validation of a Thermal Resistance and Capacity Model for Geothermal Boreholesen
typestandard
page8
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian