CSA C68.10-14

Shielded power cable for commercial and industrial applications, 5–46 kV - Second Edition; Incorporating Errata: June 2015

Organization:
CSA - CSA Group
Year: 2014

Abstract: This Standard applies to the materials, construction, and testing of oneTo four-conductor cross-linked polyethylene and ethylene propylene rubber-insulated shielded power cables, rated 5–46 kV, that are used for the distribution of electrical energy under normal conditions of installation and service in indoor, outdoor, aerial, underground, or underwater locations.
This Standard specifies requirements for conductors, insulation, and protective coverings as well as for the construction and dimensions of most standard types of shielded cable.
This Standard does not preclude the use of optional components such as polymeric layers for additional mechanical protection, moisture-impervious laminated sheath, individually covered steel wire armour, or optical fibres, provided that the components meet the performance requirements of this Standard. Test procedures for these optional components are not included in this Standard.
The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application
URI: https://yse.yabesh.ir/std/handle/yse/179977
Collections :
  • CSA - CSA Group
  • Download PDF : (2.206Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA C68.10-14

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T17:56:53Z
date available2017-09-04T17:56:53Z
date copyright2014.01.01
date issued2014
identifier otherFNIWKFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/179977
description abstractThis Standard applies to the materials, construction, and testing of oneTo four-conductor cross-linked polyethylene and ethylene propylene rubber-insulated shielded power cables, rated 5–46 kV, that are used for the distribution of electrical energy under normal conditions of installation and service in indoor, outdoor, aerial, underground, or underwater locations.
This Standard specifies requirements for conductors, insulation, and protective coverings as well as for the construction and dimensions of most standard types of shielded cable.
This Standard does not preclude the use of optional components such as polymeric layers for additional mechanical protection, moisture-impervious laminated sheath, individually covered steel wire armour, or optical fibres, provided that the components meet the performance requirements of this Standard. Test procedures for these optional components are not included in this Standard.
The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application
languageEnglish
titleCSA C68.10-14num
titleShielded power cable for commercial and industrial applications, 5–46 kV - Second Edition; Incorporating Errata: June 2015en
typestandard
page125
statusActive
treeCSA - CSA Group:;2014
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian