CSA CAN/CSA-C22.2 NO. 60601-2-50-10

English -- Medical electrical equipment — Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment - Second Edition; Incorporates Corrigendum 1: June 2011;
French -- Appareils électromédicaux – Partie 2-50: Règles particulières de sécurité des appareils de photothérapie pour nouveau-nés - Second Edition; Incorporates Corrigendum 1: June 2011

Organization:
CSA - CSA Group
Year: 2010

Abstract: Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT PHOTOTHERAPY EQUIPMENT, as defined in 201.3.203 of this standard, also referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard.
NOTE See also 4.2 of the general standard.
This particular standard specifies safety requirements for INFANT PHOTOTHERAPY EQUIPMENT, but alternate methods of compliance with a specific clause by demonstrating equivalent safety will not be judged as non-compliant if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device.
This particular standard does not apply to:
– devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use, for information see IEC 80601-2-35;
– INFANT INCUBATORS; for information see IEC 60601-2-19;
– INFANT TRANSPORT INCUBATORS; for information, see IEC 60601-2-20;
– INFANT RADIANT WARMERS; for information see IEC 60601-2-21.
URI: https://yse.yabesh.ir/std/handle/yse/180511
Collections :
  • CSA - CSA Group
  • Download PDF : (1.163Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA CAN/CSA-C22.2 NO. 60601-2-50-10

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T17:57:25Z
date available2017-09-04T17:57:25Z
date copyright2010.01.01
date issued2010
identifier otherFORSMEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/180511
description abstractReplacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT PHOTOTHERAPY EQUIPMENT, as defined in 201.3.203 of this standard, also referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard.
NOTE See also 4.2 of the general standard.
This particular standard specifies safety requirements for INFANT PHOTOTHERAPY EQUIPMENT, but alternate methods of compliance with a specific clause by demonstrating equivalent safety will not be judged as non-compliant if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device.
This particular standard does not apply to:
– devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use, for information see IEC 80601-2-35;
– INFANT INCUBATORS; for information see IEC 60601-2-19;
– INFANT TRANSPORT INCUBATORS; for information, see IEC 60601-2-20;
– INFANT RADIANT WARMERS; for information see IEC 60601-2-21.
languageEnglish, French
titleCSA CAN/CSA-C22.2 NO. 60601-2-50-10num
titleEnglish -- Medical electrical equipment — Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment - Second Edition; Incorporates Corrigendum 1: June 2011en
titleFrench -- Appareils électromédicaux – Partie 2-50: Règles particulières de sécurité des appareils de photothérapie pour nouveau-nés - Second Edition; Incorporates Corrigendum 1: June 2011other
typestandard
page92
statusActive
treeCSA - CSA Group:;2010
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian