ASHRAE 63.1

Method of Testing Liquid Line Refrigerant Driers

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2001

Abstract: This standard applies only to those driers that employ a desiccant.
A desiccant's performance varies with respect to its activation. The water capacity test method prescribed in this standard can be used to test a drier either "as received" or after being reactivated in accordance with the manufacturer's recommendations.
This standard applies only to liquid line driers for use in systems employing halocarbon refrigerants that have an atmospheric boiling point below 20°C (68°F).
This standard does not attempt to reflect the complete performance of a drier. Specifically, the following topics are not considered:
a. the physical characteristics of the desiccants,
b. the chemical characteristics of the desiccants,
c. the mechanism of water adsorption,
d. the filtration ability of a drier,
e. the acid adsorption of a drier,
f. the performance of a drier in other than a liquid line,
g. the speed of drying, h. the drier water capacity needed in relation to the size of a system, potential freeze-up problems, or potential chemical activity problems, or
i. the effect of oil on a drier's performance.
This standard defines methods of testing but does not specify the standard rating conditions for temperature, equilibrium point dryness, pressure drop, etc. ARI Standard 7107 is suggested as a reference for these values.
PURPOSE
The purpose of this standard is to prescribe test methods for determining flow capacity and water capacity performance characteristics of liquid line refrigerant driers.
URI: https://yse.yabesh.ir/std/handle/yse/180739
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (7.088Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE 63.1

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T17:57:37Z
date available2017-09-04T17:57:37Z
date copyright06/29/1995 (R 2001)
date issued2001
identifier otherFPIVWAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/180739
description abstractThis standard applies only to those driers that employ a desiccant.
A desiccant's performance varies with respect to its activation. The water capacity test method prescribed in this standard can be used to test a drier either "as received" or after being reactivated in accordance with the manufacturer's recommendations.
This standard applies only to liquid line driers for use in systems employing halocarbon refrigerants that have an atmospheric boiling point below 20°C (68°F).
This standard does not attempt to reflect the complete performance of a drier. Specifically, the following topics are not considered:
a. the physical characteristics of the desiccants,
b. the chemical characteristics of the desiccants,
c. the mechanism of water adsorption,
d. the filtration ability of a drier,
e. the acid adsorption of a drier,
f. the performance of a drier in other than a liquid line,
g. the speed of drying, h. the drier water capacity needed in relation to the size of a system, potential freeze-up problems, or potential chemical activity problems, or
i. the effect of oil on a drier's performance.
This standard defines methods of testing but does not specify the standard rating conditions for temperature, equilibrium point dryness, pressure drop, etc. ARI Standard 7107 is suggested as a reference for these values.
PURPOSE
The purpose of this standard is to prescribe test methods for determining flow capacity and water capacity performance characteristics of liquid line refrigerant driers.
languageEnglish
titleASHRAE 63.1num
titleMethod of Testing Liquid Line Refrigerant Driersen
typestandard
page9
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2001
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian