UL 17

UL Standard for Safety Vent or Chimney Connector Dampers for Oil-Fired Appliances - Fourth Edition; Reprint with Revisions through and Including September 25, 2013

Organization:
UL - UL
Year: 2008

Abstract: These requirements cover electrically operated damper assemblies, that are intended for installation in the vent or chimney connector of automatically operated oil-fired appliances employing an atomizing type oil burner. The damper assembly is intended to restrict or block the connector opening when the burner is not firing.
These requirements cover automatic vent or chimney connector dampers for oil-fired appliances having a flue gas temperature not in excess of 538°C (1000°F), unless marked for a lower temperature. See 5.1.1, 20.5.1, and 33.1(d).
The vent or chimney connector dampers covered under these requirements are not for use on oil-fired appliances that employ vaporizing type oil burners.
Automatic vent or chimney connector dampers are intended for installation in accordance with the following standards of the National Fire Protection Association:
a) Oil-Burning Equipment, NFPA 31.
b) Chimneys, Fireplaces, and Vents, NFPA 211.
c) National Electrical Code, ANSI/NFPA 70.
A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire or of electric shock or injury to persons shall be evaluated using appropriate additional component and end-product requirements to maintain the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard does not comply with this standard. Revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.
URI: https://yse.yabesh.ir/std/handle/yse/181778
Collections :
  • UL - UL
  • Download PDF : (637.8Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 17

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T17:58:41Z
date available2017-09-04T17:58:41Z
date copyright04/30/2008
date issued2008
identifier otherFSCHGFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/181778
description abstractThese requirements cover electrically operated damper assemblies, that are intended for installation in the vent or chimney connector of automatically operated oil-fired appliances employing an atomizing type oil burner. The damper assembly is intended to restrict or block the connector opening when the burner is not firing.
These requirements cover automatic vent or chimney connector dampers for oil-fired appliances having a flue gas temperature not in excess of 538°C (1000°F), unless marked for a lower temperature. See 5.1.1, 20.5.1, and 33.1(d).
The vent or chimney connector dampers covered under these requirements are not for use on oil-fired appliances that employ vaporizing type oil burners.
Automatic vent or chimney connector dampers are intended for installation in accordance with the following standards of the National Fire Protection Association:
a) Oil-Burning Equipment, NFPA 31.
b) Chimneys, Fireplaces, and Vents, NFPA 211.
c) National Electrical Code, ANSI/NFPA 70.
A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire or of electric shock or injury to persons shall be evaluated using appropriate additional component and end-product requirements to maintain the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard does not comply with this standard. Revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.
languageEnglish
titleUL 17num
titleUL Standard for Safety Vent or Chimney Connector Dampers for Oil-Fired Appliances - Fourth Edition; Reprint with Revisions through and Including September 25, 2013en
typestandard
page58
statusActive
treeUL - UL:;2008
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian