ASHRAE OR-16-C015

Optimizing the Flammability and Performance of Next Generation Low GWP R410A Replacements

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2016

Abstract: Lower global warming potential (GWP) refrigerant replacements for R410A have been extensively studied over the past few years with limited success in finding an optimal replacement. Refrigerant candidates offered to date have been a trade-off of GWP to performance, but so far candidates have not been offered that trade GWP to flammability while preserving or improving performance of R410A to allow for quick and orderly transition to lower GWP refrigerants. These refrigerants have been either pure R32 or blends of R32 with various new olefin refrigerants, like R1234yf and R1234ze(E), along with other traditional hydrofluorocarbons. Pure R32 has good performance, but would require significant hardware redesign to accommodate fluid properties differences, the GWP is one of the highest (GWP=675), as well as being one of the more flammable refrigerants (burning velocity 6.7 cm/sec). Performance modelling, unit performance testing, and flammability studies were conducted to guide the best refrigerant design to optimize GWP to flammability for blends of R32, R1234yf and R125. This study determined that in fact flammability can be minimized while allowing for a R410A “design compatible” refrigerant that improves on the performance of R410A while balancing GWP.
URI: https://yse.yabesh.ir/std/handle/yse/182090
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (898.6Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE OR-16-C015

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T17:58:54Z
date available2017-09-04T17:58:54Z
date copyright2016.01.01
date issued2016
identifier otherFSXPOFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/182090
description abstractLower global warming potential (GWP) refrigerant replacements for R410A have been extensively studied over the past few years with limited success in finding an optimal replacement. Refrigerant candidates offered to date have been a trade-off of GWP to performance, but so far candidates have not been offered that trade GWP to flammability while preserving or improving performance of R410A to allow for quick and orderly transition to lower GWP refrigerants. These refrigerants have been either pure R32 or blends of R32 with various new olefin refrigerants, like R1234yf and R1234ze(E), along with other traditional hydrofluorocarbons. Pure R32 has good performance, but would require significant hardware redesign to accommodate fluid properties differences, the GWP is one of the highest (GWP=675), as well as being one of the more flammable refrigerants (burning velocity 6.7 cm/sec). Performance modelling, unit performance testing, and flammability studies were conducted to guide the best refrigerant design to optimize GWP to flammability for blends of R32, R1234yf and R125. This study determined that in fact flammability can be minimized while allowing for a R410A “design compatible” refrigerant that improves on the performance of R410A while balancing GWP.
languageEnglish
titleASHRAE OR-16-C015num
titleOptimizing the Flammability and Performance of Next Generation Low GWP R410A Replacementsen
typestandard
page8
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian