UL 67

UL Standard for Safety Panelboards - Twelfth Edition; Reprint with Revisions Through and Including April 24, 2015

Organization:
UL - UL
Year: 2009

Abstract: These requirements cover panelboards to be employed in accordance with the National Electrical Code, NFPA 70.
These requirements cover panelboards for the control and protection of electric lighting and appliance branch circuits, and power circuits, including feeder distribution panelboards. They also cover units specifically designed for panelboard assembly.
These requirements do not cover:
a) Distribution equipment which sole function is the automatic or nonautomatic transferring of one or more load conductor connections from one power source to another. Reference the Standard for Transfer Switch Equipment, UL 1008.
b) Factory wired assemblies of industrial control equipment intended to control industrial processes. Reference the Standard for Industrial Control Panels, UL 508A.
c) Distribution equipment containing only one circuit subdivision, unless also provided with a meter socket. See 5.5.1. Reference the Standard for Molded-Case Circuit Breakers, Molded- Case Switches and Circuit-Breaker Enclosures, UL 489.
d) Distribution equipment intended to serve as a means for distributing power required to operate mobile or temporarily installed equipment. Reference the Standard for Power Outlets, UL 231.
e) Factory wired assemblies of controllers, timers, temperature regulating equipment and such, intended for control of equipment for use with swimming pools, hot tubs, and/or spas. Reference the Standard for Electric Spas, Equipment Assemblies, and Associated Equipment, UL 1563.
f) Factory wired assemblies intended for the control of Architectural and Floating Fountains. Reference the Standards for Motor-Operated Water Pumps, UL 778, Underwater Luminaires and Submersible Junction Boxes, UL 676 and Industrial Control Panels, UL 508A.
g) Portable power distribution equipment. Reference the Standard for Portable Power- Distribution Equipment, UL 1640.
h) Panelboards with converter and/or inverter functions, intended for use as distribution equipment in recreational vehicles. Reference the Standard for Power Converters/Inverters and Power Converter/Inverter Systems for Land Vehicles and Marine Crafts, UL 458.
URI: https://yse.yabesh.ir/std/handle/yse/184033
Collections :
  • UL - UL
  • Download PDF : (1.197Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 67

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T18:01:00Z
date available2017-09-04T18:01:00Z
date copyright2009.03.18
date issued2009
identifier otherFYCIKFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/184033
description abstractThese requirements cover panelboards to be employed in accordance with the National Electrical Code, NFPA 70.
These requirements cover panelboards for the control and protection of electric lighting and appliance branch circuits, and power circuits, including feeder distribution panelboards. They also cover units specifically designed for panelboard assembly.
These requirements do not cover:
a) Distribution equipment which sole function is the automatic or nonautomatic transferring of one or more load conductor connections from one power source to another. Reference the Standard for Transfer Switch Equipment, UL 1008.
b) Factory wired assemblies of industrial control equipment intended to control industrial processes. Reference the Standard for Industrial Control Panels, UL 508A.
c) Distribution equipment containing only one circuit subdivision, unless also provided with a meter socket. See 5.5.1. Reference the Standard for Molded-Case Circuit Breakers, Molded- Case Switches and Circuit-Breaker Enclosures, UL 489.
d) Distribution equipment intended to serve as a means for distributing power required to operate mobile or temporarily installed equipment. Reference the Standard for Power Outlets, UL 231.
e) Factory wired assemblies of controllers, timers, temperature regulating equipment and such, intended for control of equipment for use with swimming pools, hot tubs, and/or spas. Reference the Standard for Electric Spas, Equipment Assemblies, and Associated Equipment, UL 1563.
f) Factory wired assemblies intended for the control of Architectural and Floating Fountains. Reference the Standards for Motor-Operated Water Pumps, UL 778, Underwater Luminaires and Submersible Junction Boxes, UL 676 and Industrial Control Panels, UL 508A.
g) Portable power distribution equipment. Reference the Standard for Portable Power- Distribution Equipment, UL 1640.
h) Panelboards with converter and/or inverter functions, intended for use as distribution equipment in recreational vehicles. Reference the Standard for Power Converters/Inverters and Power Converter/Inverter Systems for Land Vehicles and Marine Crafts, UL 458.
languageEnglish
titleUL 67num
titleUL Standard for Safety Panelboards - Twelfth Edition; Reprint with Revisions Through and Including April 24, 2015en
typestandard
page188
statusActive
treeUL - UL:;2009
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian